{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G6304LSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G6304LSEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G6304LSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G6304LSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G6304LSEN, 4-pole contactor, 630 A AC-3, 200-500 V AC/DC coil, dark grey.","salesMarkdown":"The LC1G6304LSEN is a 4-pole TeSys Giga contactor rated for 630 A in AC-3 duty, with a 200-500 V AC/DC coil. The coil uses built-in bidirectional peak limiting, so you don't need external suppression. Rated insulation voltage is 1000 V, and the contactor carries a making capacity of 7220 A at 440 V and a breaking capacity of 5550 A at 440 V — that's the short-circuit capability when coordinating with upstream protection. The utilisation categories cover AC-3, AC-3e, AC-1, AC-5a, AC-5b, AC-6a, AC-6b, DC-1, DC-3, and DC-5. For resistive loads (AC-1), the thermal current Ith is 1050 A per pole. The contactor is rated for vibrations up to 4 gn when closed and shocks up to 15 gn — figures that matter on conveyors or mobile equipment. Power circuit terminals accept busbars up to 52 x 20 mm or ring lugs up to 185 mm². Control circuit uses push-in terminals for 0.2-2.5 mm² wire. The connection pitch is 70 mm, and tightening torque is 58 N·m on the power terminals. Safety reliability data is available: B10d = 100,000 cycles at nominal load and 1,800,000 cycles at mechanical load per EN/ISO 13849-1. The auxiliary contact block is 1 NO + 1 NC built-in. ## Sourcing posture This is an active catalog item in the TeSys Giga range. No direct replacement needed; it's the current-generation part.","metaTitle":"Schneider Electric LC1G6304LSEN TeSys Giga Contactor, 630 A,","metaDescription":"TeSys Giga LC1G6304LSEN 4-pole contactor, 630 A AC-3, 200-500 V AC/DC coil. UL/CSA/CE. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Color":"Dark grey","Depth":"10.5 in (266 mm)","Range":"TeSys","Width":"11.06 in (281 mm)","title":"LC1G6304LSEN","Height":"11.2 in (284 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","description":"Contactor, high power, TeSys Giga, 4P(4NO), AC-1, <=440V 1050A, standard version, 200-500V AC/DC wide band coil","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"2.8 in (70 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.000065 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"513.3 lbf.in (58 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5","Contactor application":"Power switching","Mechanical durability":"5 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"630 A aM at 500 A aM at 1250 A gG at 1000 A UL Type L at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1","inrush power in W (DC)":"390 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 52 x 20 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"5550 A at 440 V","Pole contact composition":"4 NO","Safety reliability level":"B10d = 100000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 1800000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"7220 A at 440 V","Power dissipation per pole":"70 W AC-1 - Ith 1050 A 26 W AC-3 - Ith 630 A","[Uc] control circuit voltage":"200...500 V AC 50/60 Hz 200...500 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"630 A (at 1050 A (at <104 °F (40 °C)) at <= 1000 V AC-1","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"670 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"11 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"5.05 kA - 10 s 4.4 kA - 30 s 3.4 kA - 1 min 2.2 kA - 3 min 1.6 kA - 10 min","[Ith] conventional free air thermal current":"1050 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8ecba7a41430395052876a36cba5f039.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1G6304LSEN/contactor-high-power-tesys-giga-4p4no-ac1-440v-1050a-standard-version-200500v-ac-dc-wide-band-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"630 A in AC-3 duty, 200-500 V AC/DC coil, 1000 V rated insulation voltage, 7220 A making capacity at 440 V, 5550 A breaking capacity at 440 V."},{"question":"What compliance documentation does Schneider provide?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and UL 60335-1/-2-40. RoHS/REACH declarations are standard with the brand."},{"question":"What is the physical size and color?","answer":"Dark grey enclosure. Dimensions: 11.2 in (284 mm) height, 11.06 in (281 mm) width, 10.5 in (266 mm) depth."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G6304LSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G6304LSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}