{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G630XXEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G630XXEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G630XXEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G630XXEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G630XXEN, 3-pole contactor, 630 A, 500 kW at 690 V AC-3, plate mount, dark grey.","salesMarkdown":"It switches motor loads up to 500 kW at 690 V AC-3 (600 hp at 460/480 V 60 Hz) and carries a thermal current (Ith) of 1050 A in AC-1 duty. The utilisation categories cover AC-1, AC-3, AC-3e, AC-4, and DC-1/3/5, so it handles resistive heating, standard squirrel-cage motors, high-inertia loads, and DC switching. Built-in bidirectional peak limiting coil technology means the control circuit handles the inrush without external suppression — the coil holds at 600 V AC/DC and draws 400 W on DC inrush. Closing time runs 40...70 ms, opening 15...50 ms. The 630 A frame size and 500 kW at 690 V AC-3 rating tell you this contactor is sized for large motor centres, pump stations, and compressor skids on 400 V to 690 V three-phase networks. The AC-3e rating (optimised for energy-efficient IE3/IE4 motors) matches the same power levels as AC-3 but with a defined switching duty for premium-efficiency machines — a distinction that matters when the motor nameplate calls for it. Power dissipation per pole runs 70 W at Ith 1050 A (AC-1) and 26 W at 630 A (AC-3). The plate mount (not DIN rail) and bolted power connections (bar or ring terminals up to 185 mm²) mean it is built into a backplate or chassis, not snapped onto a rail. That is a high-duty-cycle machine — suitable for frequent starting applications like conveyors or crushers where the contactor cycles multiple times per minute. ## Standards and safety Certified to EN/IEC 60947-4-1 and -5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1/-5-1. Overvoltage category III, IP2X front face with shrouds per IEC 60529 and VDE 0106. Safety reliability data is published: B10d = 100,000 cycles at nominal load, 1,800,000 cycles with mechanical load per EN/ISO 13849-1 — usable in safety-related control systems up to the given B10d values. ## Integration notes Dimensions are 284 mm high, 211 mm wide, 266 mm deep. Mounting is on a plate with a 70 mm connection pitch. Power circuit connections use bolted bars or ring terminals up to 185 mm²; control circuit uses push-in terminals accepting 0.2...2.5 mm² solid/stranded or 0.25...2.5 mm² flexible with ferrule. Tightening torque for power connections is 58 N·m. Auxiliary contact block comes as 1 NO + 1 NC built-in. The associated fuse recommendation is 630 A aM or 1250 A gG at the respective voltage levels — coordinate the upstream protection with the contactor's rated breaking capacity of 5550 A at 440 V and making capacity of 7220 A at 440 V.","metaTitle":"Schneider Electric TeSys Giga LC1G630XXEN Contactor, 630 A,","metaDescription":"Schneider Electric TeSys Giga LC1G630XXEN 3-pole contactor. Rated 630 A, switches up to 500 kW at 690 V AC-3. UL/CSA/IEC certified. Current production. Sourced to order against RFQ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Color":"Dark grey","Depth":"10.5 in (266 mm)","Range":"TeSys","Width":"8.3 in (211 mm)","title":"LC1G630XXEN","Height":"11.2 in (284 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1","description":"High power contactor,TeSys Giga,3P(3NO),AC-3 <=440V 630A,standard version,600V AC/DC coil","Motor power kW":"180 kW at 230 V AC 50/60 Hz (AC-3e) 315 kW at 400 V AC 50/60 Hz (AC-3e) 335 kW at 415 V AC 50/60 Hz (AC-3e) 355 kW at 440 V AC 50/60 Hz (AC-3e) 375 kW at 500 V AC 50/60 Hz (AC-3e) 500 kW at 690 V AC 50/60 Hz (AC-3e) 450 kW at 1000 V AC 50/60 Hz (AC-3e) 200 kW at 230 V AC 50/60 Hz (AC-3) 335 kW at 400 V AC 50/60 Hz (AC-3) 375 kW at 415 V AC 50/60 Hz (AC-3) 400 kW at 440 V AC 50/60 Hz (AC-3) 400 kW at 500 V AC 50/60 Hz (AC-3) 500 kW at 690 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 180 kW at 230 V AC 50/60 Hz (AC-4) 315 kW at 400 V AC 50/60 Hz (AC-4) 335 kW at 415 V AC 50/60 Hz (AC-4) 355 kW at 440 V AC 50/60 Hz (AC-4) 375 kW at 500 V AC 50/60 Hz (AC-4) 450 kW at 690 V AC 50/60 Hz (AC-4) 355 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"2.8 in (70 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.000065 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"513.3 lbf.in (58 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"5 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"630 A aM at 500 A aM at 1250 A gG at 1000 A UL Type L at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"400 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 52 x 20 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"5550 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 100000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 1800000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"7220 A at 440 V","Maximum Horse Power Rating":"250 hp at 200/208 V 60 Hz 300 hp at 230/240 V 60 Hz 600 hp at 460/480 V 60 Hz 700 hp at 575/600 V 60 Hz","Power dissipation per pole":"70 W AC-1 - Ith 1050 A 26 W AC-3 - Ith 630 A","[Uc] control circuit voltage":"600 V AC 50/60 Hz 600 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"1050 A (at 630 A (at <140 °F (60 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"700 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"11 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"5.05 kA - 10 s 4.4 kA - 30 s 3.4 kA - 1 min 2.2 kA - 3 min 1.6 kA - 10 min","[Ith] conventional free air thermal current":"1050 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,575.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/04bd9df7a5004c2acd1898e52f54df74.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1G630XXEN/high-power-contactortesys-giga3p3noac3-440v-630astandard-version600v-ac-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The headline ratings are 630 A thermal current (Ith), 500 kW at 690 V AC-3 motor switching, and 600 hp at 460/480 V 60 Hz for North American installations. Power dissipation per pole is 70 W at full AC-1 load and 26 W at AC-3 rated current — factor that into enclosure thermal design."},{"question":"What standards does this contactor comply with?","answer":"It is certified to EN/IEC 60947-4-1 and -5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1/-5-1. Overvoltage category III, IP2X front face with shrouds."},{"question":"What is the physical size and mounting?","answer":"284 mm high x 211 mm wide x 266 mm deep. Plate mount with bolted power connections (bar or ring terminals up to 185 mm²) and push-in control terminals. Connection pitch is 70 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G630XXEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G630XXEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}