{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G8004EHES207N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G8004EHES207N","canonicalUrl":"https://aoctrl.com/schneider/LC1G8004EHES207N","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G8004EHES207N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G8004EHES207N, 4-pole contactor, 800 A, 700 hp at 460/480 V 60 Hz, 48...130 V AC/DC coil.","salesMarkdown":"The Schneider Electric TeSys Giga LC1G8004EHES207N is a 4-pole contactor rated for heavy motor switching and power control. It handles 700 hp at 460/480 V 60 Hz and 800 hp at 575/600 V 60 Hz, making it a fit for large induction motors on pumps, compressors, and conveyors in industrial plants. The 48...130 V AC/DC coil with built-in bidirectional peak limiting simplifies control wiring — no external suppression needed. Rated at 800 A in AC-1 (resistive) duty and 700 hp at 460 V in AC-3 (motor start/run), this contactor is sized for a 400–600 V motor center. The AC-3e rating at 335 kW on 400 V AC confirms it for energy-efficient motors with higher inrush. Mechanical durability of 5 Mcycles means it outlasts most drives in the cabinet — one less spare to rotate. The 70 mm connection pitch and bolted power terminals (accepting busbar up to 52 x 20 mm or lugs up to 185 mm²) demand a plate mount, not a DIN rail; plan for a dedicated backplate in the enclosure. ## Standards and compliance — what the approvals tell you Certified to EN/IEC 60947-4-1 and UL 60947-4-1, so it meets the short-circuit coordination requirements for North American and European motor branch circuits. Also carries CSA C22.2 No 60947-4-1 and JIS C8201-4-1, covering installations in Canada and Japan. The UL 60335-1 and UL 60335-2-40:Annex JJ listings extend its use to HVAC equipment — relevant if this contactor lands in a packaged chiller or air-handler panel. Mounts on a plate — no DIN rail clip. The 509 x 302 x 355 mm (H x W x D) envelope needs a backplate clear of other devices for the 58 N.m tightening torque on the power connections. The IP2X front face with shrouds meets touch protection per IEC 60529; no additional finger-duct cover needed on the front.","metaTitle":"Schneider TeSys Giga LC1G8004EHES207N Contactor, 800 A, 4-Po","metaDescription":"Schneider Electric TeSys Giga LC1G8004EHES207N 4-pole contactor, 700 hp at 460/480 V 60 Hz. EN/IEC 60947-4-1, UL 60947-4-1. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"355 mm","Range":"TeSys","Width":"302 mm","Colour":"Dark grey","Height":"509 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","Motor power hp":"300 hp at 200/208 V 60 Hz 350 hp at 230/240 V 60 Hz 700 hp at 460/480 V 60 Hz 800 hp at 575/600 V 60 Hz","Motor power kW":"200 kW at 230 V AC 50/60 Hz (AC-3e) 335 kW at 400 V AC 50/60 Hz (AC-3e) 355 kW at 415 V AC 50/60 Hz (AC-3e) 375 kW at 440 V AC 50/60 Hz (AC-3e) 425 kW at 500 V AC 50/60 Hz (AC-3e) 560 kW at 690 V AC 50/60 Hz (AC-3e) 450 kW at 1000 V AC 50/60 Hz (AC-3e) 250 kW at 230 V AC 50/60 Hz (AC-3) 450 kW at 400 V AC 50/60 Hz (AC-3) 450 kW at 415 V AC 50/60 Hz (AC-3) 450 kW at 440 V AC 50/60 Hz (AC-3) 500 kW at 500 V AC 50/60 Hz (AC-3) 560 kW at 690 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 230 V AC 50/60 Hz (AC-4) 375 kW at 400 V AC 50/60 Hz (AC-4) 355 kW at 415 V AC 50/60 Hz (AC-4) 375 kW at 440 V AC 50/60 Hz (AC-4) 400 kW at 500 V AC 50/60 Hz (AC-4) 475 kW at 690 V AC 50/60 Hz (AC-4) 400 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"70 mm","Mounting support":"Plate","Range of product":"TeSys Giga","Average impedance":"0.000065 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"58 N.m","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8b AC-8a DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"5 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Associated fuse rating":"800 A aM at 630 A aM at 1250 A gG at 1200 A UL Type L at <= 600 V","Maximum operating rate":"300 cyc/h AC-1 500 cyc/h AC-3 500 cyc/h AC-3e 150 cyc/h AC-4","inrush power in W (DC)":"790 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 52 x 20 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5...1.0 mm² with cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"5870 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 100000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 1800000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"7640 A at 440 V","Power dissipation per pole":"70 W AC-1 - Ith 1050 A 42 W AC-3 - Ith 800 A","[Uc] control circuit voltage":"48...130 V AC 50/60 Hz 48...130 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)","[Ie] rated operational current":"1050 A (at 800 A (at <60 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"990 VA","Ambient air temperature for storage":"-60...80 °C","hold-in power consumption in W (DC)":"9.5 W","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"5.5 kA - 10 s 4.6 kA - 30 s 3.6 kA - 1 min 2.6 kA - 3 min 1.7 kA - 10 min","[Ith] conventional free air thermal current":"1050 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/LC1G8004EHES207N/high-power-contactortesys-giga-s2074p4noac3-440v-800astandard-version48130v-ac-dc-wide-band-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G8004EHES207N/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to this contactor in the TeSys family?","answer":"There is no pin-compatible alternative within the same frame size. The LC1G8004EHES207N is the specific 4-pole variant with a 48...130 V AC/DC coil. A different coil voltage or pole count would require a different order code in the TeSys Giga range."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries certifications to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It also meets UL 60335-1 and UL 60335-2-40:Annex JJ for HVAC applications. Standard RoHS and REACH declarations are available from the manufacturer."},{"question":"What are the key motor power ratings for this contactor?","answer":"At 460/480 V 60 Hz it is rated for 700 hp; at 575/600 V 60 Hz for 800 hp. In AC-3e duty at 400 V 50/60 Hz it handles 335 kW. These ratings cover most large low-voltage induction motors in industrial plants."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G8004EHES207N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G8004EHES207N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}