{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G800EHES207N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G800EHES207N","canonicalUrl":"https://aoctrl.com/schneider/LC1G800EHES207N","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G800EHES207N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G800EHES207N, 3-pole contactor, 48-130 V AC/DC coil, 800 hp at 460/480 V 60 Hz, plate mount.","salesMarkdown":"The Schneider LC1G800EHES207N is a TeSys Giga three-pole contactor rated for heavy motor switching and power control up to 800 hp at 460/480 V 60 Hz or 560 kW at 690 V AC in AC-3e duty. It carries a 48-130 V AC/DC coil with built-in bidirectional peak limiting, so no external varistor or RC snubber is needed on the coil circuit. Motor power spans 300 hp at 200/208 V up to 800 hp at 575/600 V 60 Hz; on 400 V 50/60 Hz it handles 335 kW in AC-3e and 375 kW in AC-4 — meaning it covers both normal starting (AC-3e) and high-stress reversing/plugging (AC-4) without derating the coil. Power dissipation per pole is 70 W at AC-1 (1050 A Ith) and 42 W at AC-3 (800 A Ith); that heat needs ventilation in the enclosure, especially if multiple contactors are ganged. Mounts on a plate (not DIN rail) — the 70 mm connection pitch and bolted power terminals (bar or lug-ring up to 185 mm²) are sized for a panel or motor control center bucket, not a small enclosure. The control circuit uses push-in terminals (0.2-2.5 mm² solid or stranded), so wiring the coil and aux contacts is quick with no screwdriver needed. Listed as current production. This is the standard catalog part for new designs and replacement orders. It carries UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC 60947-4-1, and JIS C8201-4-1 approvals — accepted in North American, European, and Japanese panels without additional certification work.","metaTitle":"Schneider LC1G800EHES207N TeSys Giga Contactor, 800 hp at 48","metaDescription":"Schneider LC1G800EHES207N TeSys Giga contactor, 3-pole, 48-130 V AC/DC coil. Rated 800 hp at 460/480 V 60 Hz. Current production. UL/CSA/IEC 60947-4-1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"355 mm","Range":"TeSys","Width":"211 mm","Colour":"Dark grey","Height":"284 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ","Motor power hp":"300 hp at 200/208 V 60 Hz 350 hp at 230/240 V 60 Hz 700 hp at 460/480 V 60 Hz 800 hp at 575/600 V 60 Hz","Motor power kW":"200 kW at 230 V AC 50/60 Hz (AC-3e) 335 kW at 400 V AC 50/60 Hz (AC-3e) 355 kW at 415 V AC 50/60 Hz (AC-3e) 375 kW at 440 V AC 50/60 Hz (AC-3e) 425 kW at 500 V AC 50/60 Hz (AC-3e) 560 kW at 690 V AC 50/60 Hz (AC-3e) 450 kW at 1000 V AC 50/60 Hz (AC-3e) 250 kW at 230 V AC 50/60 Hz (AC-3) 450 kW at 400 V AC 50/60 Hz (AC-3) 450 kW at 415 V AC 50/60 Hz (AC-3) 450 kW at 440 V AC 50/60 Hz (AC-3) 500 kW at 500 V AC 50/60 Hz (AC-3) 560 kW at 690 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 230 V AC 50/60 Hz (AC-4) 375 kW at 400 V AC 50/60 Hz (AC-4) 355 kW at 415 V AC 50/60 Hz (AC-4) 375 kW at 440 V AC 50/60 Hz (AC-4) 400 kW at 500 V AC 50/60 Hz (AC-4) 475 kW at 690 V AC 50/60 Hz (AC-4) 400 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"70 mm","Mounting support":"Plate","Range of product":"TeSys Giga","Average impedance":"0.000065 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"58 N.m","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8b AC-8a DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"5 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Associated fuse rating":"800 A aM at 630 A aM at 1250 A gG at 1200 A UL Type L at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"790 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 52 x 20 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5...1.0 mm² with cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"5870 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 100000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 1800000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"7640 A at 440 V","Power dissipation per pole":"70 W AC-1 - Ith 1050 A 42 W AC-3 - Ith 800 A","[Uc] control circuit voltage":"48...130 V AC 50/60 Hz 48...130 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)","[Ie] rated operational current":"1050 A (at 800 A (at <60 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"990 VA","Ambient air temperature for storage":"-60...80 °C","hold-in power consumption in W (DC)":"9.5 W","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"5.5 kA - 10 s 4.6 kA - 30 s 3.6 kA - 1 min 2.6 kA - 3 min 1.7 kA - 10 min","[Ith] conventional free air thermal current":"1050 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/LC1G800EHES207N/high-power-contactortesys-giga-s2073p3noac3-440v-800astandard-version48130v-ac-dc-wide-band-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G800EHES207N/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this contactor?","answer":"It is certified to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, and referenced in IEC 60335-1 and UL 60335-1 for appliance applications."},{"question":"What is the physical size of this contactor?","answer":"Height 284 mm, width 211 mm, depth 355 mm — plate-mount, not DIN-rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G800EHES207N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G800EHES207N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}