{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G800LSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G800LSEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G800LSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G800LSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga, LC1G800LSEN, 3-pole contactor, 800 A, dark grey, 200–500 V AC/DC coil.","salesMarkdown":"The Schneider Electric TeSys Giga LC1G800LSEN is a 3-pole contactor rated for 800 A continuous current, built for heavy motor switching and power distribution. It carries motor power up to 560 kW at 690 V AC-3e and 700 hp at 460/480 V 60 Hz, so it handles large induction motors in pump, fan, compressor, and conveyor drives. The coil accepts 200–500 V AC or DC, with built-in bidirectional peak limiting to suppress inrush — no external surge suppressor needed on the coil circuit. The 800 A rating is the thermal current (Ith) in AC-1 duty; for motor loads you size by the AC-3e or AC-3 power figures. At 400 V AC-3e it switches 335 kW, so a 315 kW motor leaves headroom. The rated breaking capacity of 5870 A at 440 V and making capacity of 7640 A at 440 V confirm it clears fault currents without welding contacts — important for coordination with upstream breakers. Mechanical durability of 5 Mcycles means it outlasts most panel life; the B10d of 100,000 cycles at nominal load (EN/ISO 13849-1) is the safety-relevant figure for machine guarding circuits. The contactor meets EN/IEC 60947-4-1 and UL 60947-4-1, so it is accepted in both IEC and North American panels. The TH protective treatment adds humidity resistance for tropical or washdown environments. Plate-mount only — no DIN-rail option for this frame size. The power terminals accept bar or busbar up to 52 x 20 mm, or lugs up to 185 mm². Tightening torque is 58 N.m on the power connections, so a torque wrench is required. Connection pitch is 70 mm, which matches standard busbar spacing for panel layouts. Dimensions: 266 mm deep, 211 mm wide, 284 mm high.","metaTitle":"Schneider Electric LC1G800LSEN TeSys Giga Contactor, 800 A,","metaDescription":"Schneider Electric TeSys Giga LC1G800LSEN 3-pole contactor. Rated 800 A, 700 hp at 460/480 V. Standards: IEC 60947-4-1, UL 60947-4-1. Motor power up to 560 kW at 690 V AC-3e. Sourc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Color":"Dark grey","Depth":"10.5 in (266 mm)","Range":"TeSys","Width":"8.3 in (211 mm)","title":"LC1G800LSEN","Height":"11.2 in (284 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ","description":"Contactor, high power, TeSys Giga, 3P(3NO), AC-3, <=440V 800A, standard version, 200-500V AC/DC wide band coil","Motor power kW":"200 kW at 230 V AC 50/60 Hz (AC-3e) 335 kW at 400 V AC 50/60 Hz (AC-3e) 355 kW at 415 V AC 50/60 Hz (AC-3e) 375 kW at 440 V AC 50/60 Hz (AC-3e) 425 kW at 500 V AC 50/60 Hz (AC-3e) 560 kW at 690 V AC 50/60 Hz (AC-3e) 450 kW at 1000 V AC 50/60 Hz (AC-3e) 250 kW at 230 V AC 50/60 Hz (AC-3) 450 kW at 400 V AC 50/60 Hz (AC-3) 450 kW at 415 V AC 50/60 Hz (AC-3) 450 kW at 440 V AC 50/60 Hz (AC-3) 500 kW at 500 V AC 50/60 Hz (AC-3) 560 kW at 690 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 230 V AC 50/60 Hz (AC-4) 375 kW at 400 V AC 50/60 Hz (AC-4) 355 kW at 415 V AC 50/60 Hz (AC-4) 375 kW at 440 V AC 50/60 Hz (AC-4) 400 kW at 500 V AC 50/60 Hz (AC-4) 475 kW at 690 V AC 50/60 Hz (AC-4) 400 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"2.8 in (70 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.000065 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"513.3 lbf.in (58 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"5 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"800 A aM at 630 A aM at 1250 A gG at 1200 A UL Type L at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"390 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 52 x 20 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"5870 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 100000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 1800000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"7640 A at 440 V","Maximum Horse Power Rating":"300 hp at 200/208 V 60 Hz 350 hp at 230/240 V 60 Hz 700 hp at 460/480 V 60 Hz 800 hp at 575/600 V 60 Hz","Power dissipation per pole":"70 W AC-1 - Ith 1050 A 42 W AC-3 - Ith 800 A","[Uc] control circuit voltage":"200...500 V AC 50/60 Hz 200...500 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"1050 A (at 800 A (at <140 °F (60 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"670 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"11 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"5.5 kA - 10 s 4.6 kA - 30 s 3.6 kA - 1 min 2.6 kA - 3 min 1.7 kA - 10 min","[Ith] conventional free air thermal current":"1050 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5359dbfaa6b3d36a29326b11fd396f03.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1G800LSEN/contactor-high-power-tesys-giga-3p3no-ac3-440v-800a-standard-version-200500v-ac-dc-wide-band-coil/"},"ai":{"faq":[{"question":"What compliance standards does the LC1G800LSEN meet?","answer":"It meets EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, IEC 60335-1 Clause 30.2, IEC 60335-2-40 Annex JJ, UL 60335-1, and UL 60335-2-40 Annex JJ."},{"question":"What are the key ratings for the LC1G800LSEN?","answer":"Rated 800 A thermal current (Ith). Motor power: 560 kW at 690 V AC-3e, 700 hp at 460/480 V 60 Hz. Coil voltage: 200–500 V AC/DC. Mechanical durability: 5 Mcycles. Breaking capacity: 5870 A at 440 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G800LSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G800LSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}