{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K06013FE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K06013FE7","canonicalUrl":"https://aoctrl.com/schneider/LC1K06013FE7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K06013FE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, 3P, AC-3/AC-3e 6 A at ≤440 V, 1 NC auxiliary, 115 V AC coil, spring terminals.","salesMarkdown":"The LC1K06013FE7 is a TeSys K three-pole contactor rated for motor control in AC-3 and AC-3e duty at 6 A up to 440 V, with a 115 V AC coil. It carries one normally closed instantaneous auxiliary contact. Coil inrush is 30 VA at 20 °C, holding at 4.5 VA; heat dissipation runs 1.3 W. The coil has no built-in suppressor module, so if you are driving it from a PLC output or solid-state relay, plan an external flyback diode or RC snubber across the coil to protect the switching device. Electrical durability is 1.3 million cycles at 6 A AC-3, and 50,000 cycles at 36 A AC-4 — the AC-4 figure matters if you are jogging or inching the motor under load, which wears the contacts faster. Mechanical durability is 10 million cycles, so the mechanical life is rarely the constraint in a control panel. Minimum switching capability is 5 mA at 17 V for signalling circuits — useful if the auxiliary contact feeds a low-power PLC input or indicator, but verify the load is above that threshold to avoid contact film issues. The contactor is rated for safety-related applications with a B10d of 1,369,863 cycles at nominal load per EN/ISO 13849-1. That is a statistical reliability figure for the dangerous failure rate — useful if you are calculating the PFHd for a safety circuit. Operating time is 10 to 20 ms for both coil energisation and de-energisation, with a non-overlap distance of 0.5 mm between NO and NC poles — fast enough for most sequencing but not a high-speed transfer switch. Maximum operating rate is 3600 cycles per hour, or one operation per second — fine for frequent cycling in packaging or material handling. Certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4, and JIS C8201-4-1 — covers most global markets without a separate variant. Also listed to IEC 60335-1 and UL 60335-2-40 for appliance applications. Shock and vibration ratings are given per IEC 60068-2-27 and -2-6 — the contactor stays closed under 10 Gn on X and 15 Gn on Y/Z axes, which is robust for mobile or rail equipment.","metaTitle":"Schneider TeSys K LC1K06013FE7 Contactor, 3P, 6A AC-3, 115V","metaDescription":"Active production. TeSys K contactor, 3 poles, 6 A AC-3/AC-3e at ≤440 V, 1 NC aux, 115 V AC coil. Spring terminals, 45x58x57 mm. UL, CSA, IEC 60947-4-1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","title":"LC1K06013FE7","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","description":"Contactor, TeSys K, 3P, AC-3/AC-3e, <=440V 6A, aux. 1NC, 115V AC coil","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Mounting support":"Rail Plate","Device short name":"LC1K","Poles description":"3P","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue 1.3 Mcycles 6 A AC-3e at Ue 0.05 Mcycles 36 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NC","Connections - terminals":"Spring terminals 1 cable(s) 0.75...1.5 mm²solid Spring terminals 1 cable(s) 0.75...1.5 mm²flexible without cable end Spring terminals 2 cable(s) 0.75...1.5 mm²flexible without cable end","IP degree of protection":"IP2X conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f51e2c8e594f24e495a634364be50b77.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1K06013FE7/contactor-tesys-k-3p-ac3-ac3e-440v-6a-aux-1nc-115v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 3-pole contactor rated 6 A in AC-3/AC-3e duty at ≤440 V, with a 115 V AC coil. It has one normally closed auxiliary contact, spring terminals, and measures 45 x 58 x 57 mm. Electrical durability is 1.3 million cycles at 6 A AC-3."},{"question":"What compliance documentation does this brand provide for the LC1K06013FE7?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4, and JIS C8201-4-1. It also meets IEC 60335-1 and UL 60335-2-40 for appliance use. Flame retardance is V1 per UL 94."},{"question":"What is the closest alternative to the LC1K06013FE7 in the TeSys K family?","answer":"Within the TeSys K range, the closest alternative would be a variant with a different coil voltage (e.g., 24 V AC or 230 V AC) or a different auxiliary contact configuration. The core 6 A AC-3 rating and 3-pole frame are shared across the LC1K06xxx series. For a direct pin-compatible swap, match the coil voltage and auxiliary contact count."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K06013FE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K06013FE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}