{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K06013P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K06013P7","canonicalUrl":"https://aoctrl.com/schneider/LC1K06013P7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K06013P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider LC1K06013P7 Tesys K Contactors — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview The LC1K06013P7 is a Schneider TeSys K three-pole contactor, rated for AC-3 and AC-3e switching at 6 A up to 440 V, with a 230 V AC 50/60 Hz coil and one normally-closed instantaneous auxiliary contact. Spring terminals accept 0.75–1.5 mm² solid or flexible wire; the unit mounts on plate or DIN rail and carries UL, CSA, CCC, and EAC certifications. Rated for AC-3 and AC-3e utilization categories, the LC1K06013P7 handles motor starting and stopping at 6 A rated operational current. Electrical endurance reaches 1.3 million cycles at 6 A AC-3, with mechanical life rated at 10 million cycles. Maximum operating rate is 3600 cycles per hour. The coil draws 4.5 W holding power and dissipates 1.3 W as heat; no built-in suppressor module is included, so external suppression is required for inductive loads. ## Applications TeSys K contactors of this size are specified for controlling small motors, fans, pumps, conveyors, and lighting circuits in panel builds, OEM machinery, and commercial HVAC equipment where space is tight and spring terminals speed wiring. The LC1K06013P7 is an active, current-production part within Schneider's TeSys K range. It carries multiple international certifications (CB, CCC, UL, CSA, EAC, CE, UKCA) and is compliant with EN/IEC 60947-4-1 and UL 60947-4-1 standards.","metaTitle":"Schneider LC1K06013P7 TeSys K Contactor, 3P, 6A, 230V AC, Spring Terminal","metaDescription":"Schneider TeSys K LC1K06013P7 contactor: 3 poles, AC-3/AC-3e 6A at 440V, 230V AC 50/60Hz coil, 1NC aux, spring terminals, UL/CSA/CCC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Mounting support":"Plate Rail","Device short name":"LC1K","Poles description":"3P","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue 1.3 Mcycles 6 A AC-3e at Ue 0.05 Mcycles 36 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NC","Connections - terminals":"Spring terminals 1 cable(s) 0.75...1.5 mm²solid Spring terminals 1 cable(s) 0.75...1.5 mm²flexible without cable end Spring terminals 2 cable(s) 0.75...1.5 mm²flexible without cable end","IP degree of protection":"IP2X conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$48.71","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f90de91eb17f10ca69328cbd4b5a25f7.pdf","sourceUrl":"https://www.se.com/nl/en/product/LC1K06013P7/contactor-tesys-k-3p-ac3-ac3e440v-6a-1nc-aux-230v-ac-50-60hz-coilspring-terminal/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K06013P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K06013P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}