{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K06016FLS207","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K06016FLS207","canonicalUrl":"https://aoctrl.com/schneider/LC1K06016FLS207","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K06016FLS207","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LC1K series, 3-pole contactor, LC1K06016FLS207, 1.8 W coil with integral suppression, 1 NC auxiliary contact, IP20.","salesMarkdown":"The Schneider Electric TeSys LC1K06016FLS207 is a 3-pole contactor with a 1.8 W coil that includes an integral suppression device, rated for motor control in AC-3, AC-3e, and AC-4 utilization categories. It carries one normally closed (1 NC) instantaneous auxiliary contact alongside the three NO main power poles, which is typical for a holding-circuit interlock or status feedback. Rated for AC-3 and AC-4 duty per IEC 60947-4-1, this contactor is sized for switching motor loads under both normal running (AC-3) and inching/plugging (AC-4) conditions — a distinction that matters when the application includes frequent jogging or reversing. The 1.8 W inrush and hold-in power at 20 °C means the coil driver sees a modest load, and the integral suppression device handles the back-EMF spike, so no external flyback diode or RC snubber is needed across the coil terminals. Electrical durability is listed at 1.3 million cycles at 6 A AC-3 up to 440 V, with mechanical durability at 30 million cycles — the electrical figure is the limiting factor for motor-load life, while the mechanical figure governs auxiliary-signal or low-current use. Power-circuit connections use lugs or ring terminals with a tightening torque of 0.8 to 1.3 N·m, compatible with a 3.2 mm flat, Philips No 2, or Pozidriv No 2 screwdriver. The 57 mm depth and 58 mm height should be checked against enclosure depth limits, especially when mounted with an overload relay or auxiliary block alongside. Certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4, and JIS C8201-4-1, covering the major global markets for motor-contactor applications. Flame retardance is V0 per UL 94, and the protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance.","metaTitle":"Schneider TeSys LC1K06016FLS207 Contactor, 3P, 1.8W Coil","metaDescription":"TeSys LC1K contactor, 3P, AC-3/AC-4 rated, 1.8W coil with suppression, 1 NC aux. Current production, sourced to order. UL/CSA/IEC 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing","Product weight":"0.235 kg","Coil technology":"With integral suppression device","lifecycle_stage":"current","Flame retardance":"V0 conforming to UL 94","Heat dissipation":"1.8 W","Mounting support":"Plate Rail","Device short name":"LC1K","Inrush power in W":"1.8 W (at 20 °C)","Poles description":"3P","Tightening torque":"Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm flat Ø 6 mm Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm Philips No 2 Power circuit: 0.8...1.3 N.m - on lugs-ring terminals pozidriv No 2","Device application":"Control","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue <= 440 V","Mechanical durability":"30 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NC","Connections - terminals":"Power circuit: lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP20 conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at <50 °C)","Hold-in power consumption in W":"1.8 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b9b989e7ac2922f03a2b216b27fa7985.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K06016FLS207/contactor-tesys-k-3p-ac3-440v-6a-1nc-aux-110v-dc-low-consumption-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K06016FLS207/alternatives.json"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative in this family?","answer":"Within the TeSys LC1K series, the closest alternative would be a contactor with the same 3-pole, 1 NC auxiliary configuration but a different coil voltage rating — the coil voltage is encoded in the suffix of the order code. For a direct form-fit-function swap, match the coil voltage and auxiliary count exactly."},{"question":"What compliance documentation does this part carry?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4, and JIS C8201-4-1. Flame retardance is V0 per UL 94."},{"question":"What is the depth of this contactor?","answer":"The depth is 57 mm, with a width of 45 mm and a height of 58 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K06016FLS207","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K06016FLS207 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}