{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K06016SLS207","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K06016SLS207","canonicalUrl":"https://aoctrl.com/schneider/LC1K06016SLS207","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K06016SLS207","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K series, LC1K06016SLS207, 3-pole contactor, AC-3 ≤440V 6A, 1NC auxiliary contact, 72V DC low-consumption coil with integral suppression.","salesMarkdown":"The Schneider Electric TeSys K LC1K06016SLS207 is a 3-pole contactor rated for AC-3, AC-3e, and AC-4 duty at 6 A up to 440 V, making it a direct fit for switching small motor loads in control panels. The 72 V DC coil with integral suppression draws 1.8 W hold-in power at 20 °C, so it's sized for low-energy control circuits where a standard 24 V or 110 V coil won't match the bus voltage. The built-in suppression means you don't need an external flyback diode or RC snubber across the coil — one less component to source and mount. The AC-3 rating at 6 A governs motor switching up to that current — the rating that matters for a BOM line driving a fractional-horsepower pump, fan, or conveyor. Electrical durability is 1.3 million cycles at 6 A AC-3, so it's not a one-shot part; it holds up in cyclic duty. Mechanical durability is 30 million cycles, which outlasts the electrical life in most applications. Minimum switching is 5 mA at 17 V for the signalling circuit, meaning it can handle low-level PLC inputs without contact wetting issues. That's a real advantage when the aux contact feeds a 24 V DC digital input card — no false opens from oxide film. The 57 mm depth, 45 mm width, and 58 mm height fit the standard TeSys K footprint, so it drops into an existing DIN-rail or plate-mounted layout without re-spacing. The contactor carries EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4, and JIS C8201-4-1 approvals — so it's accepted in North American, European, Chinese, and Japanese installations without a separate UL/CSA variant. Flame retardance is V0 per UL 94, which satisfies the panel flammability requirements for most industrial control enclosures. ## Deployment context The lugs-ring terminals accept ring tongues with a 7 mm outer diameter, torqued to 0.8–1.3 N·m using a 3.2 mm flat or Philips No 2 screwdriver — no special tooling needed.","metaTitle":"Schneider TeSys K LC1K06016SLS207 Contactor, 3P AC-3 6A, 72V","metaDescription":"Schneider Electric TeSys K LC1K06016SLS207 contactor, 3-pole, AC-3 6A at ≤440V, 1NC aux, 72V DC low-consumption coil. Active production. UL/CSA/IEC. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing","Coil technology":"With integral suppression device","lifecycle_stage":"current","Flame retardance":"V0 conforming to UL 94","Heat dissipation":"1.8 W","Mounting support":"Plate Rail","Device short name":"LC1K","Inrush power in W":"1.8 W (at 20 °C)","Poles description":"3P","Tightening torque":"Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm flat Ø 6 mm Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm Philips No 2 Power circuit: 0.8...1.3 N.m - on lugs-ring terminals pozidriv No 2","Device application":"Control","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue <= 440 V","Mechanical durability":"30 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NC","Connections - terminals":"Power circuit: lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP20 conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at <50 °C)","Hold-in power consumption in W":"1.8 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b43625f8f951e1f2356c1a9987ea531d.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K06016SLS207/contactor-tesys-k-3p-ac3-440v-6a-1nc-aux-72v-dc-low-consumption-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K06016SLS207/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide for LC1K06016SLS207?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4, and JIS C8201-4-1. Flame retardance is V0 per UL 94."},{"question":"What is the closest alternative to LC1K06016SLS207 in the TeSys K family?","answer":"Within the TeSys K range, the primary variant difference is the coil voltage. The LC1K0601* series shares the same pole configuration and ratings; the LC1K06016SLS207 specifically uses a 72 V DC low-consumption coil with integral suppression. A 24 V DC or 110 V DC coil variant would be a different order code but the same form, fit, and function for the power circuit."},{"question":"What is LC1K06016SLS207's listed depth?","answer":"The depth is 57 mm, with a width of 45 mm and height of 58 mm."},{"question":"What is LC1K06016SLS207's listed range?","answer":"It belongs to the Schneider Electric TeSys K range of contactors."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K06016SLS207","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K06016SLS207 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}