{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K06103K7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K06103K7","canonicalUrl":"https://aoctrl.com/schneider/LC1K06103K7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K06103K7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K series, LC1K06103K7, 3-pole contactor, 6 A rated operational current in AC-3/AC-3e at 440 V, 100 V AC 50/60 Hz coil, 1 NO auxiliary contact, spring terminals.","salesMarkdown":"The Schneider Electric LC1K06103K7 is a TeSys K series 3-pole contactor rated for motor control in AC-3 and AC-3e utilisation categories, switching 6 A at 440 V. The 100 V AC coil draws 30 VA inrush and 4.5 VA hold-in at 20 °C. The spring terminals accept 0.75 to 1.5 mm² solid or flexible cable, and the 1 NO auxiliary contact provides a signalling circuit rated down to 5 mA and 17 V. The AC-3 rating of 6 A at 440 V governs motor switching — it handles the inrush of a small motor up to that current, not just resistive loads. Electrical durability is 1.3 million cycles at 6 A AC-3, dropping to 50,000 cycles at 36 A AC-4 for plugging or inching duty. Mechanical durability is 10 million cycles, so the contactor outlasts its electrical life under normal motor starts. The IP2X finger protection (VDE 0106) means it is safe for open-panel mounting where accidental contact is a concern.","metaTitle":"TeSys K LC1K06103K7 Contactor, 3P, 6A AC-3, 100V AC Coil","metaDescription":"Obsolete TeSys K LC1K06103K7 contactor. 3P, 6A AC-3/AC-3e at 440V, 100V AC coil, 1NO aux. Sourced to order against RFQ. Multiple standards compliance.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Mounting support":"Plate Rail","Device short name":"LC1K","Poles description":"3P","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue 1.3 Mcycles 6 A AC-3e at Ue 0.05 Mcycles 36 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NO","Connections - terminals":"Spring terminals 1 cable(s) 0.75...1.5 mm²solid Spring terminals 1 cable(s) 0.75...1.5 mm²flexible without cable end Spring terminals 2 cable(s) 0.75...1.5 mm²flexible without cable end","IP degree of protection":"IP2X conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b71dde7bbd665edc25d6f3d14a4c4759.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K06103K7/contactor-tesys-k-3p-ac3-ac3e440v-6a-aux-1no-100v-ac-standard-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K06103K7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC1K06103K7?","answer":"It is a 3-pole contactor rated 6 A in AC-3/AC-3e at 440 V, with a 100 V AC coil. It includes 1 NO auxiliary contact and spring terminals for 0.75–1.5 mm² cable."},{"question":"What compliance standards does the LC1K06103K7 meet?","answer":"It complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and IEC 60335-1 Clause 30.2. Flame retardance is V1 per UL 94."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K06103K7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K06103K7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}