{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K06106FLS207","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K06106FLS207","canonicalUrl":"https://aoctrl.com/schneider/LC1K06106FLS207","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K06106FLS207","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LC1K contactor, 3-pole, 6 A AC-3, 24 VDC coil with integral suppression, plate/rail mount, IP20.","salesMarkdown":"The Schneider Electric TeSys LC1K06106FLS207 is a 3-pole contactor rated for motor control in AC-3 and AC-4 duty, with a 24 VDC coil that includes an integral suppression device. It switches loads up to 6 A in AC-3 category, which covers typical squirrel-cage motor starting and running — the rating that governs real-world fit for pumps, fans, and small conveyors. The coil holds in at 24 VDC nominal, with an operational range of 0.7 to 1.3 Uc and a drop-out threshold at or above 0.10 Uc below 50 °C. Inrush and hold-in power both sit at 1.8 W at 20 °C, so the thermal load on the control transformer is predictable — no hidden surge. Rated for AC-3 and AC-4 utilization categories per EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. The 6 A AC-3 rating at up to 440 V gives 1.3 million electrical cycles — enough for frequent starting in a packaging or material-handling line. Mechanical durability is 30 million cycles, so the contactor outlasts most machinery refreshes. Minimum switching capability is 5 mA at 17 V for the signalling circuit, which means it can reliably switch PLC-level dry-contact signals without welding or oxidation issues. The single normally-open auxiliary contact is instantaneous, rated for the same signalling circuit frequency up to 400 Hz. The contactor carries a B10d of 1,369,863 cycles at nominal load per EN/ISO 13849-1, making it usable in safety-related control systems where reliability data is required for the performance level calculation. IP20 finger-safe protection per VDE 0106 means it can live in an open control cabinet without additional shrouding. Power connections use ring-lug terminals with a tightening torque of 0.8 to 1.3 N·m, accepting a 3.2 mm flat or Philips No 2 screwdriver.","metaTitle":"TeSys LC1K06106FLS207 Contactor, 3P, 6 A AC-3, 24 VDC Coil","metaDescription":"Schneider Electric TeSys LC1K06106FLS207 contactor, 3-pole, 6 A AC-3, 24 VDC coil with integral suppression. Active production. UL/CSA/IEC. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing","Product weight":"0.235 kg","Coil technology":"With integral suppression device","lifecycle_stage":"current","Flame retardance":"V0 conforming to UL 94","Heat dissipation":"1.8 W","Mounting support":"Plate Rail","Device short name":"LC1K","Inrush power in W":"1.8 W (at 20 °C)","Poles description":"3P","Tightening torque":"Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm flat Ø 6 mm Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm Philips No 2 Power circuit: 0.8...1.3 N.m - on lugs-ring terminals pozidriv No 2","Device application":"Control","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue <= 440 V","Mechanical durability":"30 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NO","Connections - terminals":"Power circuit: lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP20 conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at <50 °C)","Hold-in power consumption in W":"1.8 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0ac6f7be34663597ce9211ef29fb29d5.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K06106FLS207/contactor-tesys-k-3p-ac3-440v-6a-1no-aux-110v-dc-low-consumption-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K06106FLS207/alternatives.json"},"ai":{"faq":[{"question":"What are the key standards this contactor complies with?","answer":"It complies with EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Flame retardance is V0 per UL 94."},{"question":"What is the minimum load this contactor can switch reliably?","answer":"The signalling circuit can switch down to 5 mA at 17 V, so it handles dry-contact PLC inputs without problems."},{"question":"What is the operating temperature range?","answer":"Storage temperature is -50 to 80 °C; permissible ambient air temperature around the device is -40 to 70 °C at Uc."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K06106FLS207","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K06106FLS207 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}