{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K06106L7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K06106L7","canonicalUrl":"https://aoctrl.com/schneider/LC1K06106L7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K06106L7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K series, LC1K06106L7, 3-pole contactor, AC-3/AC-3e 6A at 440V, 200-208V AC standard coil, 1 NO auxiliary contact.","salesMarkdown":"The Schneider Electric LC1K06106L7 is a TeSys K series 3-pole contactor rated for motor control in AC-3 and AC-3e utilisation categories at 6 A up to 440 V, with an additional AC-4 rating for inching/jogging duty. The coil is a 200-208 V AC standard type without a built-in suppressor module, so you will need to add an RC snubber or varistor across the coil if driving it from a PLC output or solid-state relay. It carries a single normally-open instantaneous auxiliary contact (1 NO) for feedback or interlocking. The contactor is rated for 10 million mechanical cycles and 1.3 million electrical cycles at the AC-3 rating, with a maximum operating rate of 3600 cycles per hour. The physical footprint (57 mm depth, 45 mm width, 58 mm height) and ring-lug terminal style are consistent across the K-frame contactors. The AC-3 rating of 6 A at 440 V governs motor switching — this contactor is sized for small three-phase motors up to roughly 2.2 kW at 400 V. The AC-4 rating drops to 36 A but only for 50,000 cycles, reflecting the severe duty of plugging or inching. If your application requires frequent reversing or jogging, factor that reduced electrical life into your maintenance schedule. The coil draws 30 VA inrush and 4.5 VA holding at 20 °C, dissipating 1.3 W. The control circuit operates from 0.8 to 1.15 times the rated coil voltage and drops out at 0.2 times Uc below 50 °C. Minimum switching capability is 5 mA at 17 V for the signalling circuit, so it can interface with low-level PLC inputs without issues. Standards compliance includes EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, plus IEC 60335-1 and UL 60335-2-40 for appliance applications. The IP2X finger protection rating (VDE 0106) means it is safe for open-panel mounting but not for washdown environments.","metaTitle":"TeSys K LC1K06106L7 Contactor, 3P, 6A AC-3, 200-208V Coil","metaDescription":"Obsolete TeSys K LC1K06106L7 contactor. 3P, 6A AC-3 at 440V, 200-208V AC coil, 1NO aux. Sourced to order against RFQ via authorized channel.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Device short name":"LC1K","Poles description":"3P","Tightening torque":"0.8...1.3 N.m - on lugs-ring terminals Philips No 2 0.8...1.3 N.m - on lugs-ring terminals flat Ø 6 mm 0.8...1.3 N.m - on lugs-ring terminals pozidriv No 2","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue 1.3 Mcycles 6 A AC-3e at Ue 0.05 Mcycles 36 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NO","Connections - terminals":"Lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP2X conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b2c0c3ea9bdf76ff9897793252ee5f63.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K06106L7/contactor-tesys-k-3p-ac3-ac3e440v-6a-aux-1no-200-208v-ac-standard-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K06106L7/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC1K06106L7?","answer":"The direct successor within the TeSys K family is the LC1K0610x7 series with the same 200-208 V AC coil voltage. Verify the auxiliary contact configuration (1 NO) matches your requirement before ordering."},{"question":"What are the key ratings for this contactor?","answer":"It is a 3-pole contactor rated 6 A in AC-3 at 440 V for motor control, with a 200-208 V AC coil. It includes one normally-open auxiliary contact and is rated for 10 million mechanical cycles."},{"question":"What compliance certifications does it carry?","answer":"It complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, IEC 60335-1, and UL 60335-2-40. It also meets NF F 16-101 for railway fire safety."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K06106L7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K06106L7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}