{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K06106M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K06106M7","canonicalUrl":"https://aoctrl.com/schneider/LC1K06106M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K06106M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, LC1K06106M7, 3-pole, 6 A AC-3/AC-3e at 440 V, 220…230 V AC standard coil, 1 NO auxiliary contact.","salesMarkdown":"The Schneider Electric LC1K06106M7 is a TeSys K 3-pole contactor rated 6 A in AC-3 / AC-3e duty at 440 V, with a 220…230 V AC standard coil and one normally-open auxiliary contact. It is designed for motor control in control panels, switching inductive loads up to that current. Electrical durability is 1.3 million cycles at that AC-3 rating, so it holds up for a long production run. The coil holds in at 0.8 to 1.15 times nominal voltage and drops out at 0.2 times nominal, giving a clean margin for brownout conditions. The contactor carries a B10d of 1.37 million cycles under nominal load per EN/ISO 13849-1, which is relevant if you are integrating it into a safety-related control system. The 57 mm depth and 45 mm width fit standard DIN-rail enclosures. The LC1K06106M7 is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, covering the major industrial markets globally. It also meets IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ for appliance and HVAC applications, and carries V1 flame retardance per UL 94.","metaTitle":"Schneider Electric LC1K06106M7 TeSys K Contactor, 6A AC-3, 2","metaDescription":"Schneider Electric LC1K06106M7 TeSys K contactor, 3P, 6A AC-3 at 440V, 220-230V AC coil, 1 NO aux. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","title":"LC1K06106M7","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","description":"Contactor, TeSys K, 3P, AC-3/AC-3e,440V 6A, aux. 1NO, 220...230V AC standard coil","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Device short name":"LC1K","Poles description":"3P","Tightening torque":"0.8...1.3 N.m - on lugs-ring terminals Philips No 2 0.8...1.3 N.m - on lugs-ring terminals flat Ø 6 mm 0.8...1.3 N.m - on lugs-ring terminals pozidriv No 2","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue 1.3 Mcycles 6 A AC-3e at Ue 0.05 Mcycles 36 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NO","Connections - terminals":"Lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP2X conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a28636ed13f0cef411c16380491ddee6.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1K06106M7/contactor-tesys-k-3p-ac3-ac3e440v-6a-aux-1no-220-230v-ac-standard-coil/"},"ai":{"faq":[{"question":"What are the key standards this contactor meets?","answer":"It is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, plus IEC 60335-1 and IEC 60335-2-40 for appliance use."},{"question":"What is the coil voltage and tolerance?","answer":"The coil is rated 220…230 V AC. Operational range is 0.8 to 1.15 times nominal; dropout occurs at 0.2 times nominal below 50 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K06106M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K06106M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}