{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K0610F7TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K0610F7TQ","canonicalUrl":"https://aoctrl.com/schneider/LC1K0610F7TQ","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K0610F7TQ","rawCanonicalId":null},"summary":{"shortDescription":"Square D LC1K0610F7TQ 6A Contactor|Square D LC1K0610F7TQ 6A Contactor","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"2.2 in (57 mm)","Width":"1.8 in (45 mm)","Height":"2.3 in (58 mm)","Category":"US10I1222326","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"10...20 ms coil de-energisation and NO opening 15...25 ms coil de-energisation and NC opening 10...20 ms between energisation of coil and closing of NO contact 5...15 ms coil energisation and NC opening","Coil technology":"Without built-in suppressor module","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"Class C2 conforming to NF F 16-101 Class C2 conforming to NF F 16-102 V1 conforming to UL 94","Mounting Support":"Rail Plate","Device short name":"LC1K","Poles description":"3P","Inrush power in VA":"30 VA (at 68 °F (20 °C))","Operating altitude":"6561.68 ft (2000 m) without derating","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 1.3 Mcycles 6 A AC-3e 0.05 Mcycles 36 A AC-4 <= 440 V","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"3600 cyc/h","Connections - terminals":"screw clamp terminals 1 0.002...0.006 in² (1.5...4 mm²)solid screw clamp terminals 1 0.001...0.006 in² (0.75...4 mm²)flexible without cable end screw clamp terminals 1 0.0005...0.004 in² (0.34...2.5 mm²)flexible with cable end screw clamp terminals 2 0.002...0.006 in² (1.5...4 mm²)solid screw clamp terminals 2 0.001...0.006 in² (0.75...4 mm²)flexible without cable end screw clamp terminals 2 0.0005...0.002 in² (0.34...1.5 mm²)flexible with cable end","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Minimum switching current":"5 mA for control circuit","Minimum switching voltage":"17 V for control circuit","Product or Component Type":"Contactor","Control circuit voltage limits":"Operational: 0.8...1.15 Uc at 50/60 Hz (at Drop-out: >= 0.20 Uc at 50/60 Hz (at <122 °F (50 °C))","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit Signalling circuit 10 MOhm for control circuit","Hold-in power consumption in VA":"4.5 VA 50/60 Hz (at 68 °F (20 °C))","Ambient Air Temperature for Storage":"-58...176 °F (-50...80 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$58.09","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc2ade12536e4db4432f29b54c804769.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K0610F7TQ/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K0610F7TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K0610F7TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}