{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K0610M7TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K0610M7TQ","canonicalUrl":"https://aoctrl.com/schneider/LC1K0610M7TQ","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K0610M7TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, 3 poles, AC-3/AC-3e 6A at 440V, coil 220...230V AC, screw clamp terminals, plate/rail mount.","salesMarkdown":"The Schneider LC1K0610M7TQ is a 3-pole contactor from the TeSys K series, rated 6 A in AC-3/AC-3e utilisation category at 440 V, with a 220...230 V AC coil. It is designed for motor control applications — switching three-phase induction motors on and off in control panels and machinery. The AC-3 rating (6 A at 440 V) means it handles starting and stopping of squirrel-cage motors under load — the standard duty for a contactor this size. AC-3e extends that rating for energy-efficient motors with higher inrush. The 3 NO power poles handle the motor circuit; there are no built-in auxiliary contacts on this variant. Screw clamp terminals accept 1.5 to 4 mm² solid or 0.34 to 2.5 mm² flexible with ferrule — typical for control panel wiring up to this current class. Certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1 — the core contactor and motor-starter standards across Europe, North America, and Japan. That means it is accepted in panels destined for most industrial markets without additional re-certification. Also meets GB/T 14048.4 for China. Flame retardance rated V1 per UL 94 and Class C2 per NF F 16-101/102 (railway fire protection). These matter when the contactor sits in a panel that must pass a vertical-flame or railway fire-safety audit. Electrical durability: 1.3 million cycles at 6 A AC-3, but only 50,000 cycles at 36 A AC-4 (plugging/reversing duty). If your application involves frequent inching or reversing, expect a shorter service life — plan spares accordingly. Mechanical durability is 10 million cycles, so the mechanism outlasts the electrical contacts under heavy AC-4 duty. Coil hold-in power is 4.5 VA at 50/60 Hz, with an inrush of 30 VA at 20 °C. The coil operates from 0.8 to 1.15 times the rated control voltage and drops out at 0.2 Uc — standard for this class. No built-in suppressor module, so plan for an external RC snubber or varistor if driving the coil from a PLC output. Minimum switching capability: 5 mA at 17 V for the control circuit. That is low enough to switch PLC-level signals directly, but verify the load current stays above that threshold to avoid contact oxidation in dry-switching applications. Safety reliability: B10d of 1,369,863 cycles with nominal load per EN/ISO 13849-1 — relevant if this contactor is used in a safety-related control system. For mechanical load only (no current switching), B10d rises to 20 million cycles.","metaTitle":"Schneider LC1K0610M7TQ TeSys K Contactor, 3P, 6A AC-3, 220-2","metaDescription":"Obsolete Schneider TeSys K contactor LC1K0610M7TQ, 3 poles, 6A AC-3/AC-3e at 440V, coil 220-230VAC. Sourced to order against RFQ. UL/CSA/IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"10...20 ms coil de-energisation and NO opening 15...25 ms coil de-energisation and NC opening 10...20 ms between energisation of coil and closing of NO contact 5...15 ms coil energisation and NC opening","Coil technology":"Without built-in suppressor module","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"Class C2 conforming to NF F 16-101 Class C2 conforming to NF F 16-102 V1 conforming to UL 94","Mounting support":"Plate Rail","Device short name":"LC1K","Poles description":"3P","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue 1.3 Mcycles 6 A AC-3e at Ue 0.05 Mcycles 36 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Maximum operating rate":"3600 cyc/h","Connections - terminals":"Screw clamp terminals 1 cable(s) 1.5...4 mm²solid Screw clamp terminals 1 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34...2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5...4 mm²solid Screw clamp terminals 2 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34...1.5 mm²flexible with cable end","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for control circuit","Minimum switching voltage":"17 V for control circuit","Product or component type":"Contactor","Control circuit voltage limits":"Operational: 0.8...1.15 Uc at 50/60 Hz (at Drop-out: >= 0.20 Uc at 50/60 Hz (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for control circuit","Hold-in power consumption in VA":"4.5 VA 50/60 Hz (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/LC1K0610M7TQ/contactor-tesys-k-3-poles-ac3-ac3e440v-6a-coil-220-230v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K0610M7TQ/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LC1K0610M7TQ?","answer":"It is a 3-pole contactor rated 6 A in AC-3/AC-3e at 440 V, with a 220...230 V AC coil. It mounts on plate or DIN rail and uses screw clamp terminals."},{"question":"What standards does the LC1K0610M7TQ comply with?","answer":"It complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and GB/T 14048.4. It also meets UL 94 V1 flame retardance and NF F 16-101/102 Class C2 for railway applications."},{"question":"How do I source the LC1K0610M7TQ since it is obsolete?","answer":"We can quote it to order against an RFQ through our surplus and broker network. Submit an RFQ and we will check availability from last-time-buy inventory or new-old-stock sources."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K0610M7TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K0610M7TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}