{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K0610P7S335","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K0610P7S335","canonicalUrl":"https://aoctrl.com/schneider/LC1K0610P7S335","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K0610P7S335","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K LC1K0610P7S335, 3-pole contactor, 6 A AC-3 at 440 V, 1 NO aux, 230 V AC coil, screw clamp terminals, DIN-rail mount.","salesMarkdown":"It is rated for AC-3 and AC-4 utilisation categories, meaning it is designed to switch motor loads — AC-3 covers starting and stopping squirrel-cage motors, while AC-4 covers plugging and inching duty. The headline rating is 6 A at 440 V in AC-3, which tells you the maximum motor current it can handle under those conditions; for a 230 V motor the same contactor can carry a higher current, but the 440 V figure is the one that governs the BOM line for 400 V-class systems. The coil is 230 V AC, with an operational voltage range of 0.8...1.15 Uc and a drop-out threshold of ≥ 0.20 Uc below 50 °C. Inrush power is 30 VA at 20 °C, dropping to 4.5 VA hold-in — a standard AC magnet coil curve. The contactor is supplied without a built-in suppressor module, so you will need to add an RC snubber or varistor across the coil if the PLC output or relay driving it requires one. The footprint is 45 mm wide by 58 mm high by 57 mm deep — a compact form factor that fits in a crowded enclosure. Screw clamp terminals accept 1.5...4 mm² solid or 0.34...2.5 mm² flexible with cable end, torqued to 0.8...1.3 N·m. ## Lifecycle and compliance — sourcing posture For a project buyer freezing a BOM, this part is a standard catalog item — no PCN risk, no last-time-buy clock. The multi-standard compliance means one part number covers the panel regardless of whether the end customer specifies IEC or UL. ## Durability and mechanical robustness Mechanical durability is rated at 10 million cycles, while electrical durability depends on the load: 1.3 million cycles at 6 A AC-3 or AC-3e, dropping to 50,000 cycles at 36 A AC-4 at ≤ 440 V. Shock and vibration ratings are given for both closed and open contactor states: the contactor withstands 10 Gn on X and 15 Gn on Y/Z axes when closed, and 6 Gn on X / 10 Gn on Y/Z when open, all per IEC 60068-2-27. The safety reliability figure B10d is 1,369,863 cycles with nominal load per EN/ISO 13849-1, and 20 million cycles with mechanical load only. This matters if the contactor is used in a safety-related control circuit — the B10d value feeds the MTTFd calculation for the safety function. The non-overlap distance is 0.5 mm, which is the guaranteed gap between NO and NC contacts during transition; this prevents a momentary short-circuit when switching between them in interlocking circuits. Minimum switching capability is 5 mA at 17 V for the signalling circuit — important if the auxiliary contact is used to drive a PLC input with a low wetting current. Below that threshold, oxide films on the silver contacts may not break down reliably, so do not use this contact for dry-circuit logic-level switching. Operating altitude is 2000 m without derating. Above that, the dielectric strength and thermal dissipation both degrade; the contactor can still function but the rated operational voltage and current must be reduced per IEC 60947-1.","metaTitle":"Schneider Electric LC1K0610P7S335 TeSys K Contactor, 3P, 6A","metaDescription":"Schneider Electric TeSys K contactor LC1K0610P7S335, 3 poles, 6 A AC-3 at 440 V, 1 NO auxiliary contact, 230 V AC coil. Active production. UL/CSA/IEC certified. DIN-rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Mounting support":"Plate Rail","Device short name":"LC1K","Poles description":"3P","Tightening torque":"0.8...1.3 N.m - on screw clamp terminals Philips No 2 0.8...1.3 N.m - on screw clamp terminals flat Ø 6 mm 0.8...1.3 N.m - on screw clamp terminals pozidriv No 2","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Electrical durability":"1.3 Mcycles 6 A AC-3 at Ue 1.3 Mcycles 6 A AC-3e at Ue 0.05 Mcycles 36 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NO","Connections - terminals":"Screw clamp terminals 1 cable(s) 1.5...4 mm²solid Screw clamp terminals 1 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34...2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5...4 mm²solid Screw clamp terminals 2 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34...1.5 mm²flexible with cable end","IP degree of protection":"IP20 conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1ee0cf5dd3e36794e4d41a28915d9210.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K0610P7S335/contactor-tesys-k-3p-ac3-440v-6a-aux-1no-230v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K0610P7S335/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"The LC1K0610P7S335 is a 3-pole contactor rated 6 A in AC-3 at 440 V, with a 230 V AC coil. It includes one built-in NO auxiliary contact. Mechanical durability is 10 million cycles; electrical durability is 1.3 million cycles at 6 A AC-3. Heat dissipation is 1.3 W."},{"question":"What compliance standards does this part meet?","answer":"It is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4, and JIS C8201-4-1. Flame retardance is V1 per UL 94. IP20 finger-safe protection per VDE 0106."},{"question":"What is the closest alternative in the TeSys K family?","answer":"The closest peer is the LC1K0610P7, which shares the same 6 A AC-3 rating, 3-pole configuration, and 1 NO auxiliary contact, but with a 24 V AC coil instead of 230 V AC. The physical footprint and terminal layout are identical, so a panel swap requires only a coil voltage change."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K0610P7S335","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K0610P7S335 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}