{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K090083P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K090083P7","canonicalUrl":"https://aoctrl.com/schneider/LC1K090083P7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K090083P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LC1K090083P7, 4-pole contactor, 20 A AC-1 rated operational current, 230 V AC 50/60 Hz coil, spring terminals, plate/rail mount.","salesMarkdown":"The Schneider Electric LC1K090083P7 is a TeSys-series 4-pole contactor built for switching resistive loads. It carries a 20 A rated operational current in AC-1 utilisation category at up to 690 V AC, with a 230 V AC 50/60 Hz coil. The contact arrangement is 2 NO + 2 NC, and the terminals are spring-cage type accepting 0.75…1.5 mm² solid or flexible wire. The 230 V AC coil is standard for European control circuits; the coil pulls 30 VA inrush at 20 °C and dissipates 1.3 W holding. The 2 NO + 2 NC main poles give you flexibility for switching both phases or using one set as an auxiliary interlock. Spring terminals save panel-builder time — no screw torque to verify, just strip 8 mm and push in. The IP2X finger protection (VDE 0106) means it's safe for open-panel mounting where accidental contact is possible.","metaTitle":"Schneider Electric LC1K090083P7 TeSys Contactor, 20 A AC-1,","metaDescription":"Schneider Electric LC1K090083P7 TeSys contactor, 20 A rated operational current (AC-1), 230 V AC 50/60 Hz coil, 4-pole (2 NO + 2 NC), spring terminals, current lifecycle status, co","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing 15...25 ms coil de-energisation and NC closing 5...15 ms coil energisation and NC opening","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Mounting support":"Plate Rail","Average impedance":"3 mOhm - Ith 16 A 50 Hz for power circuit","Device short name":"LC1K","Poles description":"4P","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Control circuit type":"AC at 50/60 Hz","Overvoltage category":"III","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"0.16 Mcycles 20 A AC-1 at Ue <= 690 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Connections - terminals":"Spring terminals 1 cable(s) 0.75...1.5 mm²solid Spring terminals 1 cable(s) 0.75...1.5 mm²flexible without cable end Spring terminals 2 cable(s) 0.75...1.5 mm²flexible without cable end","IP degree of protection":"IP2X conforming to VDE 0106","Rated breaking capacity":"110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"110 A AC for power circuit conforming to IEC 60947","Signalling circuit frequency":"<= 400 Hz","[Uc] control circuit voltage":"230 V AC 50/60 Hz","[Ui] rated insulation voltage":"Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"2 NO + 2 NC","[Ie] rated operational current":"20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: Signalling circuit: <= 690 V AC <= 400 Hz","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit","[Ith] conventional free air thermal current":"16 A (at 60 °C) for power circuit 10 A (at 50 °C) for signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ba704cb5271000651c0124a7dcca8340.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K090083P7/contactor-tesys-k-4p2no+2nc-ac1-440v-20a-230v-ac-coil-spring-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K090083P7/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this contactor carry?","answer":"It is certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It also meets IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ for glow-wire, with V1 flame retardance per UL 94."},{"question":"What is the closest pin-compatible alternative in the TeSys family?","answer":"Within the TeSys LC1K range, the closest alternative would be a contactor with the same 4-pole arrangement and coil voltage, but with a different current rating — for example, the LC1K090083P7 is a 20 A AC-1 part; a sibling like LC1K120083P7 would offer a higher 25 A AC-1 rating in the same physical footprint and terminal style. The deciding factor is your load current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K090083P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K090083P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}