{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K09013D7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K09013D7","canonicalUrl":"https://aoctrl.com/schneider/LC1K09013D7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K09013D7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 9 A, 1 NC aux, 42 V AC coil, 4 kW motor capacity at 480 V.","salesMarkdown":"The LC1K09013D7 is a 3-pole TeSys K contactor from Schneider Electric, rated for 9 A in AC-3 utilisation category at voltages up to 440 V. That AC-3 rating governs motor switching — it's the duty cycle that matters for starting and stopping squirrel-cage induction motors under load. The coil is 42 V AC, with one normally closed auxiliary contact built in. ## Motor power capacity across voltages This contactor handles 4 kW motor loads at 480 V, 500–600 V, and 660–690 V AC 50/60 Hz. Drop to 220–230 V and the rating is 2.2 kW. That voltage flexibility means the same part works across 230 V, 400 V, and 690 V line supplies — useful when panel designs span multiple regions or voltage classes. Status is active per Schneider's lifecycle record — no phase-out or NRND flag. That means it's still a standard catalog line, not a last-time-buy scavenger hunt. Heat dissipation is 1.3 W, so no special ventilation required in a standard IP2X enclosure. Flame retardance meets UL 94 V1 and NF F 16-101/102 Requirement 2, which covers rail and transit applications. ## Short-time withstand and utilisation range Rated short-time withstand current (Icw) for the power circuit is 90 A for 1 second, 80 A for 10 seconds, and 20 A for 15 minutes or longer. That tells you the contactor can ride through fault currents long enough for an upstream breaker to clear — useful for coordination studies. Utilisation categories cover AC-1 (resistive), AC-3 (motor start/run), and AC-4 (plugging/inching), so it's not limited to motor duty alone.","metaTitle":"Schneider Electric LC1K09013D7 TeSys K Contactor, 9 A AC-3,","metaDescription":"Schneider Electric LC1K09013D7 TeSys K contactor, 3-pole, 9 A AC-3 at ≤440 V, 1 NC auxiliary, 42 V AC coil. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Product name":"TeSys K","Motor power kW":"4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 4 kW at 380...415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Range of product":"TeSys K","Poles description":"3P","Compatibility code":"LC1K","Device application":"Control","Utilisation category":"AC-3 AC-4 AC-1","Pole contact composition":"3 NO","Product or component type":"Contactor","Signalling circuit frequency":"10 MOhm for signalling circuit","[Uc] control circuit voltage":"type instantaneous 1 NC","[Icw] rated short-time withstand current":"90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ed6fe2818345447d30bb92380bb30a08.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC1K09013D7/tesys-k-contactor-3p-ac3-440-v-9-a-1-nc-aux-42-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K09013D7/alternatives.json"},"ai":{"faq":[{"question":"What motor power can this contactor handle?","answer":"At 480 V AC 50/60 Hz it handles 4 kW. Same rating at 500–600 V and 660–690 V. At 380–415 V and 440 V it also delivers 4 kW. At 220–230 V the rating drops to 2.2 kW."},{"question":"What is the coil voltage and auxiliary contact configuration?","answer":"Coil is 42 V AC. The contactor has one normally closed auxiliary contact (1 NC) built into the base unit."},{"question":"What approvals or compliance documentation does this part carry?","answer":"Flame retardance is UL 94 V1 compliant, plus NF F 16-101 and NF F 16-102 Requirement 2 for rail applications. The TeSys K series typically carries UL, CSA, and CE marks, though specific certification listings should be verified against the factory certificate for your jurisdiction."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K09013D7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K09013D7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}