{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K09013K7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K09013K7","canonicalUrl":"https://aoctrl.com/schneider/LC1K09013K7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K09013K7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, LC1K09013K7, 3P, AC-3 ≤ 440 V 9 A, 1 NC auxiliary, 100 V AC coil, 57 mm depth.","salesMarkdown":"## Product Identification and Key Ratings The LC1K09013K7 is a TeSys K three-pole contactor from Schneider Electric, rated for AC-3 duty at 9 A up to 440 V with a 100 V AC coil. It carries one normally closed auxiliary contact. The part is now classified as obsolete per the manufacturer's lifecycle status. For motor switching, the contactor is rated at 4 kW on 380–415 V AC, 480 V, 500–600 V, and 660–690 V supplies at 50/60 Hz, and 2.2 kW at 220–230 V AC. The rated operational current is 20 A, with AC-3 switching current at 9 A and AC-1 at 16 A. The contactor measures 57 mm deep, 45 mm wide, and 58 mm high, fitting standard DIN-rail enclosures. Heat dissipation is 1.3 W. The enclosure material meets flame retardance class V1 per UL 94, and also complies with NF F 16-101 and NF F 16-102 requirements. ## Sourcing and Lifecycle Position The LC1K09013K7 is obsolete. No successor order code is listed. Source this part through independent channels against an RFQ. ## Utilisation Categories and Application Context The contactor is rated for utilisation categories AC-1 (resistive loads), AC-3 (squirrel-cage motors: starting, switching off during running), and AC-4 (plugging, inching, reversing). The AC-3 rating of 9 A at ≤440 V defines its primary motor-switching capability. For audit purposes, the rated short-time withstand current (Icw) is 90 A for 1 second on the power circuit, and 110 A for 100 ms on the signalling circuit.","metaTitle":"TeSys K LC1K09013K7 Contactor, 3P AC-3 9A, 100VAC Coil","metaDescription":"Obsolete TeSys K contactor, 3P, AC-3 ≤440V 9A, 1 NC aux, 100VAC coil. Sourced to order against RFQ. 57mm depth, 45mm width. UL94 V1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Product name":"TeSys K","Motor power kW":"4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 4 kW at 380...415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Range of product":"TeSys K","Device short name":"LC1K","Poles description":"3P","Compatibility code":"LC1K","Device application":"Control","Utilisation category":"AC-4 AC-1 AC-3","Pole contact composition":"3 NO","Product or component type":"Contactor","[Ie] rated operational current":"20 A (at 9 A at 16 A (at 10 MOhm for signalling circuit","[Icw] rated short-time withstand current":"90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/506ea3af4a79106393787a1c206a2b11.pdf","sourceUrl":"https://www.se.com/in/en/product/LC1K09013K7/tesys-k-contactor-3p-ac3-440-v-9-a-1-nc-aux-100-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K09013K7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC1K09013K7?","answer":"It is a 3-pole contactor rated AC-3 at 9 A up to 440 V with a 100 V AC coil. Motor power ratings include 4 kW at 380–415 V, 480 V, 500–600 V, and 660–690 V AC, and 2.2 kW at 220–230 V AC. The contactor has one NC auxiliary contact and measures 57 mm deep by 45 mm wide by 58 mm high."},{"question":"What compliance documentation is available for this contactor?","answer":"The contactor carries flame retardance rating V1 per UL 94, and also complies with NF F 16-101 and NF F 16-102 requirements. The evidence does not list RoHS, REACH, or additional UL certification details for this specific order code."},{"question":"How can I source the LC1K09013K7 now that it is obsolete?","answer":"As an obsolete part, it is sourced through independent surplus and broker channels. Submit an RFQ for current availability and pricing; no manufacturer lead time applies."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K09013K7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K09013K7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}