{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K09015FE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K09015FE7","canonicalUrl":"https://aoctrl.com/schneider/LC1K09015FE7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K09015FE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, 3P, AC-3/AC-3e ≤440 V 9 A, 1 NC auxiliary, 115 V AC coil, solder-pin terminals.","salesMarkdown":"The Schneider Electric LC1K09015FE7 is a TeSys K three-pole contactor rated 9 A in AC-3 duty at ≤440 V, with a 115 V AC coil and one normally closed auxiliary contact. At 20 A AC-1 it handles resistive heater banks, but the 9 A AC-3 line is what you size against for a pump, fan, or conveyor motor. The 115 V AC coil draws 30 VA inrush and 4.5 VA hold-in power at 20 °C. The control voltage limits are 0.8 to 1.15 times the rated control voltage Uc for operation, and dropout occurs at ≥0.20 Uc below 50 °C — meaning the coil will reliably drop out before the voltage sags low enough to cause contact welding on a brownout. Minimum switching capability is 5 mA at 17 V for the signalling circuit, so this contactor can switch low-level PLC inputs or pilot lights without needing a separate interface relay — useful when the load side is a dry contact signal rather than a motor. ## Where it goes and what it connects to This contactor mounts on a printed circuit board via solder pins with a 0.035 mm external diameter. The 45 mm width, 58 mm height, and 57 mm depth footprint fits standard TeSys K panel layouts. IP2X finger protection per VDE 0106 means it is safe for open-panel mounting where incidental contact is possible, but not for washdown environments. The 3 NO power poles and 1 NC instantaneous auxiliary contact give you one normally closed feedback path for status monitoring or electrical interlocking without adding an auxiliary block. The 0.5 mm non-overlap distance between NO and NC transitions ensures break-before-make timing on the auxiliary circuit. ## Durability and safety reliability Electrical durability is rated at 1.3 million cycles at 9 A AC-3, 1.3 million at 9 A AC-3e, 160,000 cycles at 20 A AC-1, and 20,000 cycles at 54 A AC-4. The AC-4 figure (plugging/inching duty) is the wear-out limit — if your application does frequent reversing or inching, expect contact life around 20,000 operations at full load. Mechanical durability is 10 million cycles, so the coil and armature outlast the contacts under heavy switching. Safety reliability per EN/ISO 13849-1 gives a B10d of 1,369,863 cycles under nominal load and 20,000,000 cycles under mechanical load only. This means the contactor is suitable for safety-related control circuits up to a certain mission time — the B10d figure feeds directly into the PFHd calculation for the safety function.","metaTitle":"Schneider TeSys K LC1K09015FE7 Contactor, 3P, 9A AC-3, 115V","metaDescription":"Schneider Electric TeSys K contactor LC1K09015FE7. 3 poles, 9 A AC-3/AC-3e at ≤440 V, 1 NC aux, 115 V AC coil. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Mounting support":"Printed circuit boards","Device short name":"LC1K","Poles description":"3P","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-1 AC-4","Contactor application":"Motor control Resistive load","Electrical durability":"1.3 Mcycles 9 A AC-3 at Ue 1.3 Mcycles 9 A AC-3e at Ue 0.16 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 54 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NC","Connections - terminals":"Solder pins (external diameter: 0.035 mm)","IP degree of protection":"IP2X conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1cf4fd6e26038a04e2fb6b72627702b1.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1K09015FE7/contactor-tesys-k-3p-ac3-ac3e440v-9a-aux-1nc-115v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K09015FE7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"The LC1K09015FE7 is a 3-pole contactor rated 9 A in AC-3 duty at ≤440 V, with a 115 V AC coil drawing 30 VA inrush and 4.5 VA hold-in. It has one normally closed auxiliary contact, solder-pin terminals, and a mechanical durability of 10 million cycles."},{"question":"What compliance standards does the LC1K09015FE7 meet?","answer":"It is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and meets IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ. It also carries V1 flame retardance per UL 94 and rail standard NF F 16-101/102."},{"question":"What is the minimum switching capability?","answer":"The contactor can switch down to 5 mA at 17 V on the signalling circuit, allowing direct control of low-level PLC inputs or pilot lights without an interface relay."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K09015FE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K09015FE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}