{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K09016BLS207","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K09016BLS207","canonicalUrl":"https://aoctrl.com/schneider/LC1K09016BLS207","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K09016BLS207","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K series, LC1K09016BLS207, 3-pole contactor, 9 A AC-3 at ≤ 440 V, 24 V DC low-consumption coil, 1 NC auxiliary contact, IP20.","salesMarkdown":"The Schneider Electric LC1K09016BLS207 is a TeSys K series 3-pole contactor rated for 9 A in AC-3 utilisation category at ≤ 440 V, making it suitable for switching three-phase motor loads up to that current. It also carries AC-1 (resistive) and AC-4 (plugging/inching) ratings, so it covers general switching and high-stress motor duty. The 24 V DC coil includes an integral suppression device, which simplifies panel wiring by eliminating the need for an external flyback diode or RC snubber across the coil terminals. Coil hold-in power is 1.8 W at 20 °C, a low-consumption design that keeps heat dissipation in the enclosure manageable — relevant when multiple contactors share a DIN rail. The contactor is rated for 30 million mechanical cycles and 1.3 million electrical cycles at 9 A AC-3, giving a solid service life for typical conveyor or pump cycling. Its 45 mm width and 58 mm height fit the compact TeSys K footprint, leaving room alongside other control components in a standard 600 mm wide panel. The IP20 finger-safe enclosure (per VDE 0106) means it can be installed in a control cabinet without additional shrouding, though the power circuit terminals accept ring lugs with a 7 mm outer diameter — plan for lug clearance when laying out the gland plate. Tightening torque for the power circuit terminals is 0.8 to 1.3 N·m using a 3.2 mm flat or Philips No. 2 screwdriver. The single NC auxiliary contact is instantaneous, so it provides immediate status feedback without delay for the control logic. This contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and JIS C8201-4-1, covering the main global markets for motor control. It also meets IEC 60335-1 Clause 30.2 and the corresponding UL/CSA annexes for appliance applications, which is relevant for OEMs building equipment that must pass a household-appliance safety standard. The housing is rated V-0 flame retardance per UL 94.","metaTitle":"Schneider TeSys K LC1K09016BLS207 Contactor, 9A AC-3, 24V DC","metaDescription":"Schneider Electric TeSys K LC1K09016BLS207 3-pole contactor, 9A AC-3 at ≤440V, 24V DC low-consumption coil, 1NC aux, IP20. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","title":"LC1K09016BLS207","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","description":"Contactor, TeSys K, 3P, AC-3 <=440V 9A, 1NC aux., 24V DC low consumption coil","Operating time":"10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing","Coil technology":"With integral suppression device","lifecycle_stage":"current","Flame retardance":"V0 conforming to UL 94","Heat dissipation":"1.8 W","Mounting support":"Rail Plate","Device short name":"LC1K","Inrush power in W":"1.8 W (at 20 °C)","Poles description":"3P","Tightening torque":"Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm flat Ø 6 mm Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm Philips No 2 Power circuit: 0.8...1.3 N.m - on lugs-ring terminals pozidriv No 2","Device application":"Control","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-1 AC-4","Contactor application":"Resistive load Motor control","Electrical durability":"0.18 Mcycles 20 A AC-1 at Ue 1.3 Mcycles 9 A AC-3 at Ue <= 440 V","Mechanical durability":"30 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NC","Connections - terminals":"Power circuit: lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP20 conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at <50 °C)","Hold-in power consumption in W":"1.8 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$88.94","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9973c0ac5595860a77c04bf88d92c91c.pdf","sourceUrl":"https://www.se.com/nl/en/product/LC1K09016BLS207/contactor-tesys-k-3p-ac3-440v-9a-1nc-aux-24v-dc-low-consumption-coil/"},"ai":{"faq":[{"question":"What are the key ratings of this contactor?","answer":"It is a 3-pole contactor rated 9 A in AC-3 at ≤ 440 V, with a 24 V DC low-consumption coil (1.8 W hold-in). It includes one NC auxiliary contact and carries AC-1, AC-3e, and AC-4 utilisation categories."},{"question":"What compliance documentation is available for this part?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and JIS C8201-4-1. It also meets IEC 60335-1 Clause 30.2 for appliance applications. The housing is UL 94 V-0 rated."},{"question":"What is the physical size of the LC1K09016BLS207?","answer":"Width is 45 mm, height is 58 mm, and depth is 57 mm. It mounts on a DIN rail or plate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K09016BLS207","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K09016BLS207 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}