{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K09016M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K09016M7","canonicalUrl":"https://aoctrl.com/schneider/LC1K09016M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K09016M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys K series, LC1K09016M7, 3-pole contactor, 9 A AC-3/AC-3e at 440 V, 1 NC auxiliary contact, 220…230 V AC standard coil, IP2X.","salesMarkdown":"The Schneider LC1K09016M7 is a TeSys K three-pole contactor rated 9 A in AC-3 duty at 440 V, with a 220…230 V AC coil and one normally closed auxiliary contact. AC-3 is the standard category for squirrel-cage motor switching — the 9 A rating means it handles motor loads up to roughly 4 kW at 400 V, which is the spec that decides fit for a motor starter BOM line. It also carries AC-1 (resistive) and AC-4 (plugging/inching) ratings, so it covers resistive heater banks and reversing duty within its current limits. The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, which means it is accepted in European, North American, and Japanese panels without additional component-level testing. Flame retardance is V1 per UL 94, and the protective treatment meets IEC 60068 and DIN 50016 for tropical/humid environments. This order code is marked obsolete by the manufacturer. Mechanical durability is 10 million cycles, so the contactor outlasts its electrical life by a wide margin in lightly loaded or resistive circuits. The B10d value of 1,369,863 cycles at nominal load (per EN/ISO 13849-1) means it can be used in safety-related control circuits up to that cycle count before the failure probability exceeds the SIL/PL threshold — useful if the contactor is part of a monitored safety chain. The coil draws 30 VA inrush and 4.5 VA holding at 20 °C, with a control voltage range of 0.8…1.15 Uc operational and dropout at ≥0.20 Uc below 50 °C. Heat dissipation is 1.3 W. The lugs-ring terminals accept 7 mm ring lugs, torqued to 0.8…1.3 N·m with a Philips No 2 or flat Ø 6 mm driver. The single NC auxiliary contact is instantaneous, not timed, so it is suitable for interlocking or status feedback but not for delay-on-dropout logic. The IP2X finger protection (per VDE 0106) means it is safe for open-panel installation where operators may reach near the terminals. The 2000 m altitude rating without derating covers most installations; above that, the rated current must be reduced per IEC 60947-4-1 derating curves.","metaTitle":"Schneider LC1K09016M7 TeSys K Contactor, 3P 9A AC-3, 220-230","metaDescription":"Obsolete Schneider LC1K09016M7 TeSys K contactor, 3P, 9A AC-3 at 440V, 1NC aux, 220-230VAC coil. Sourced to order against RFQ. UL/CSA/IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ","Operating time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Device short name":"LC1K","Poles description":"3P","Tightening torque":"0.8...1.3 N.m - on lugs-ring terminals Philips No 2 0.8...1.3 N.m - on lugs-ring terminals flat Ø 6 mm 0.8...1.3 N.m - on lugs-ring terminals pozidriv No 2","Device application":"Control","Inrush power in VA":"30 VA (at 20 °C)","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-1 AC-4","Contactor application":"Resistive load Motor control","Electrical durability":"1.3 Mcycles 9 A AC-3 at Ue 1.3 Mcycles 9 A AC-3e at Ue 0.16 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 54 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NC","Connections - terminals":"Lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP2X conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <50 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Hold-in power consumption in VA":"4.5 VA (at 20 °C)","Ambient air temperature for storage":"-50...80 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4a07fbdd0dc124cdbb910431258698ef.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1K09016M7/contactor-tesys-k-3p-ac3-ac3e-440v-9a-1nc-aux-220-230v-ac-standard-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K09016M7/alternatives.json"},"ai":{"faq":[{"question":"What standards does this contactor comply with?","answer":"It is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and also meets IEC 60335-1 Clause 30.2 and UL 60335-2-40 Annex JJ for appliance applications. Flame retardance is V1 per UL 94."},{"question":"What is the physical size and mounting?","answer":"The contactor measures 45 mm wide, 58 mm high, and 57 mm deep. It uses lugs-ring terminals with 7 mm ring lugs, torqued to 0.8…1.3 N·m. It is rated IP2X finger protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K09016M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K09016M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}