{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K09016SLS207","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K09016SLS207","canonicalUrl":"https://aoctrl.com/schneider/LC1K09016SLS207","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K09016SLS207","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K series, LC1K09016SLS207, 3-pole contactor, 9 A AC-3 at ≤440 V, 72 V DC low-consumption coil with integral suppression, 1 NC auxiliary contact.","salesMarkdown":"The Schneider Electric LC1K09016SLS207 is a TeSys K series 3-pole contactor rated for 9 A in AC-3 utilisation category at ≤440 V, making it a direct fit for switching small to medium motor loads in control panels. The 72 V DC low-consumption coil draws only 1.8 W at 20 °C and includes an integral suppression device, so no external flyback diode or RC snubber is needed on the coil circuit — just wire the DC supply directly. The main poles are 3 NO, and a single 1 NC auxiliary contact is built in for feedback or interlocking. The 9 A AC-3 rating at ≤440 V is the motor-switching current — this contactor will handle a 3-phase motor drawing up to 9 A under full load, with the ability to break the motor's locked-rotor current during starting. The AC-1 rating (resistive load) is higher, but for motor duty the AC-3 figure governs selection. The 72 V DC coil operates reliably from 0.7 to 1.3 times nominal voltage (roughly 50.4 to 93.6 V DC) and drops out at ≥0.1 Uc below 50 °C. Coil energisation closes the NO contacts in 30 to 40 ms; de-energisation opens them in 10 to 20 ms. The 1.8 W hold-in power means minimal heat in a crowded panel. Mechanical durability is rated at 30 million cycles, and electrical durability at 1.3 million cycles at 9 A AC-3. The B10d value of 1,369,863 cycles under nominal load (per EN/ISO 13849-1) supports use in safety-related control circuits up to certain performance levels. The IP20 finger-safe protection (per VDE 0106) means it is suitable for installation inside an enclosed panel where no water or dust ingress is expected. Mounts on either a DIN rail or a flat plate. Power connections accept ring terminals with a 7 mm outer diameter. The 1 NC auxiliary contact is instantaneous — no delay.","metaTitle":"Schneider LC1K09016SLS207 TeSys K Contactor, 9A AC-3, 72V DC","metaDescription":"Schneider TeSys K LC1K09016SLS207 contactor, 3P, 9A AC-3 at 440V, 72V DC low-consumption coil with suppression, 1NC aux. Active production. Ships from stock.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"BS 5424 IEC 60947 NF C 63-110 VDE 0660 IEC 60077-1 IEC 60077-2 EN 45545: R22 HL3 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing","Coil technology":"With integral suppression device","lifecycle_stage":"current","Flame retardance":"V0 conforming to UL 94","Heat dissipation":"1.8 W","Mounting support":"Plate Rail","Device short name":"LC1K","Inrush power in W":"1.8 W (at 20 °C)","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-1 AC-4","Contactor application":"Motor control Resistive load","Electrical durability":"0.18 Mcycles 20 A AC-1 at Ue 1.3 Mcycles 9 A AC-3 at Ue <= 440 V","Mechanical durability":"30 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NC","Connections - terminals":"Power circuit: lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP20 conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at <50 °C)","Hold-in power consumption in W":"1.8 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/19cbe9a141f0f2c16e7aa9ba19d5c119.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K09016SLS207/contactor-tesys-k-3p-ac3-440v-9a-1nc-aux-72v-dc-low-consumption-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K09016SLS207/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 3-pole contactor rated 9 A in AC-3 at ≤440 V, with a 72 V DC low-consumption coil drawing 1.8 W hold-in power. It includes one 1 NC auxiliary contact and has a mechanical durability of 30 million cycles."},{"question":"What compliance documentation does this part carry?","answer":"It is approved to IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, EN 45545 (R22 HL3), and other standards. The housing is V-0 rated per UL 94."},{"question":"What is the closest alternative in the TeSys K family?","answer":"Within the TeSys K range, the LC1K0901 series shares the same 9 A AC-3 rating and 3-pole configuration but differs in coil voltage. The LC1K09016SLS207 specifically uses a 72 V DC low-consumption coil with integral suppression — verify coil voltage compatibility before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K09016SLS207","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K09016SLS207 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}