{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K09106FLS207","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K09106FLS207","canonicalUrl":"https://aoctrl.com/schneider/LC1K09106FLS207","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K09106FLS207","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LC1K contactor, 3-pole, 9 A AC-3, 24 VDC coil, with integral suppression, 1 NO auxiliary contact.","salesMarkdown":"## TeSys LC1K contactor, 9 A AC-3, 24 VDC coil The Schneider Electric LC1K09106FLS207 is a 3-pole contactor from the TeSys range, rated for motor control in AC-3 and AC-3e duty up to 9 A, and for resistive loads (AC-1) at 20 A. The 24 VDC coil includes integral suppression, so no external flyback diode is needed — one less component to mount and verify on the panel layout. Mechanical durability is rated at 30 million cycles, and electrical durability at 1.3 million cycles at 9 A AC-3 up to 440 V. That puts the wear-out point well beyond typical machine life for moderate-duty applications like conveyors, pumps, and small compressors — a solid fit for a production line where unplanned downtime is the metric that matters. Built-in 1 NO instantaneous auxiliary contact covers basic feedback or interlocking. If you need more, the TeSys K range offers add-on auxiliary blocks that clip onto the front without extra wiring space. The AC-1 rating (20 A) covers resistive loads like heaters. For signalling circuits, the minimum switching capability is 5 mA at 17 V, which means it can reliably switch PLC-level dry contacts without needing a separate interface relay. Safety reliability is quantified: B10d of 1,369,863 cycles at nominal load per EN/ISO 13849-1. That's the number of operations before 10% of a sample population fails dangerously — useful for SIL/PL calculations in safety-related control circuits.","metaTitle":"Schneider Electric LC1K09106FLS207 TeSys contactor, 3-pole,","metaDescription":"Schneider Electric LC1K09106FLS207 TeSys contactor, 3-pole, 9 A AC-3, 24 VDC coil. Current production. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"BS 5424 IEC 60947 NF C 63-110 VDE 0660 IEC 60077-1 IEC 60077-2 EN 45545: R22 HL3 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing","Product weight":"0.235 kg","Coil technology":"With integral suppression device","lifecycle_stage":"current","Flame retardance":"V0 conforming to UL 94","Heat dissipation":"1.8 W","Mounting support":"Plate Rail","Device short name":"LC1K","Inrush power in W":"1.8 W (at 20 °C)","Poles description":"3P","Tightening torque":"Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm flat Ø 6 mm Power circuit: 0.8...1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm Philips No 2 Power circuit: 0.8...1.3 N.m - on lugs-ring terminals pozidriv No 2","Device application":"Control","Operating altitude":"2000 m without derating","Non overlap distance":"0.5 mm","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-1 AC-4","Contactor application":"Motor control Resistive load","Electrical durability":"0.18 Mcycles 20 A AC-1 at Ue 1.3 Mcycles 9 A AC-3 at Ue <= 440 V","Mechanical durability":"30 Mcycles","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NO","Connections - terminals":"Power circuit: lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP20 conforming to VDE 0106","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Signalling circuit frequency":"<= 400 Hz","Control circuit voltage limits":"Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at <50 °C)","Hold-in power consumption in W":"1.8 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/37586f9107bee46034d1ba94808ecafa.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1K09106FLS207/contactor-tesys-k-3p-ac3-440v-9a-1no-aux-110v-dc-low-consumption-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K09106FLS207/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Three-pole, 9 A in AC-3 (motor duty) up to 440 V, 20 A in AC-1 (resistive). Coil is 24 VDC with integral suppression. Mechanical durability is 30 million cycles; electrical durability at AC-3 is 1.3 million cycles."},{"question":"What compliance standards does it meet?","answer":"Certified to IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, EN 45545 (R22 HL3) for railway fire safety, and VDE 0660. Flame retardance is V-0 per UL 94."},{"question":"What is the mounting and connection style?","answer":"Mounts on DIN rail or plate. Power connections are ring terminals (7 mm OD) with a tightening torque of 0.8–1.3 N·m. IP20 finger-safe protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K09106FLS207","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K09106FLS207 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}