{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K1210P5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K1210P5","canonicalUrl":"https://aoctrl.com/schneider/LC1K1210P5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K1210P5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, LC1K1210P5, 3-pole, 12 A in AC-3/AC-3e, 1 NO auxiliary contact, 230 V 50 Hz coil.","salesMarkdown":"The Schneider Electric LC1K1210P5 is a TeSys K series contactor — a compact 3-pole unit rated 12 A in AC-3/AC-3e duty for motor switching up to 440 V, with a 230 V 50 Hz coil and one built-in normally-open auxiliary contact. It is designed for control applications: resistive loads and motor control, covering utilisation categories AC-1, AC-3, AC-3e, and AC-4. The 12 A AC-3 rating is the motor-switching current — the contactor handles a 3-phase induction motor drawing 12 A during start and run. Electrical durability at that load is 1.3 million cycles, which is solid for a compact frame. For resistive loads (AC-1) it carries 20 A, but expect 300,000 cycles at that level. The AC-4 rating (72 A inrush for plugging/reversing) is good for only 20,000 cycles — that category is hard on contacts, so plan for shorter life in severe duty. Heat dissipation is 1.3 W holding, 30 VA inrush. That 1.3 W is low enough to stack several units in a small enclosure without forced cooling — but the 30 VA inrush spike matters for transformer sizing if you're powering multiple coils from a single control transformer. Mounting is on plate or rail (DIN rail compatible). Screw-clamp terminals accept 1.5 to 4 mm² solid or 0.34 to 2.5 mm² flexible with ferrule, torqued to 0.8–1.3 N·m. IP20 finger-safe protection per VDE 0106.","metaTitle":"Schneider Electric LC1K1210P5 TeSys K Contactor, 3P, 12A AC-","metaDescription":"Schneider Electric LC1K1210P5 TeSys K contactor, 3 poles, 12A AC-3/AC-3e, 1 NO aux, 230V 50Hz coil. Active production, UL/CSA/IEC certified. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"57 mm","Width":"45 mm","Height":"58 mm","IP Rating":"IP20","Application":"Resistive load Motor control","Operating Time":"10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing","Product Status":"Active","Temp Storage Max":"80 °C","Temp Storage Min":"-50 °C","Temperature Storage":"-50...80 °C","Utilization Category":"AC-3 AC-3e AC-1 AC-4","Electrical Life Cycles":"1.3 Mcycles 12 A AC-3 at Ue 1.3 Mcycles 12 A AC-3e at Ue 0.3 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 72 A AC-4 at Ue <= 440 V","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Contactor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a407ff76e593d67cbbe6e2376a930a7.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC1K1210P5/contactor-tesys-k-3p-12a-ac3-ac3e-440v-aux-1no-coil-230v-50hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K1210P5/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K1210P5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K1210P5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}