{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K16106N7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K16106N7","canonicalUrl":"https://aoctrl.com/schneider/LC1K16106N7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K16106N7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 16 A, 1 NO aux, 400…415 V AC coil, obsolete.","salesMarkdown":"The LC1K16106N7 is a TeSys K three-pole contactor from Schneider Electric, rated 16 A in AC-3 utilisation category at ≤440 V, with a single normally-open auxiliary contact and a 400…415 V AC coil. It is now listed as obsolete. The AC-3 rating (16 A at ≤440 V) governs motor switching duty — this contactor is sized for a 7.5 kW motor on a 380…415 V supply, or 5.5 kW at 440 V, or 4 kW at 480 V and up to 690 V. The AC-1 rating covers resistive loads at the same current level. The 400…415 V AC coil is specific to that voltage band; it will not pull in reliably on a 480 V control circuit without a dropping resistor or transformer. ## Integration notes The contactor dissipates 1.3 W at rated load — negligible for most enclosures, but worth checking if it sits next to solid-state devices in a sealed cabinet. Flame retardance is V1 per UL 94, which is standard for this class. The 3 NO main poles and 1 NO auxiliary are fixed; no field-convertible contact arrangement.","metaTitle":"TeSys K LC1K16106N7 Contactor, 16 A, 400-415 V AC Coil, Obso","metaDescription":"Obsolete TeSys K contactor, 3P, AC-3 16 A at ≤440 V, 1 NO aux, 400-415 V AC coil. Sourced to order against RFQ. Depth 57 mm, width 45 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Product name":"TeSys K","Motor power kW":"4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 4 kW at 220...230 V AC 50/60 Hz 7.5 kW at 380...415 V AC 50/60 Hz","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Heat dissipation":"1.3 W","Range of product":"TeSys K","Device short name":"LC1K","Poles description":"3P","Compatibility code":"LC1K","Device application":"Control","Utilisation category":"AC-3 AC-1","Pole contact composition":"3 NO","Product or component type":"Contactor","[Ie] rated operational current":"16 A at 20 A at 10 MOhm for signalling circuit","[Icw] rated short-time withstand current":"115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b3079e61df4fdd925ba17742f2af2191.pdf","sourceUrl":"https://www.se.com/in/en/product/LC1K16106N7/tesys-k-contactor-3p-ac3-440-v-16-a-1-no-aux-400-415-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1K16106N7/alternatives.json"},"ai":{"faq":[{"question":"What replaces LC1K16106N7?","answer":"No official successor order code is documented in the available records. A parametric substitute from the same TeSys family would need to match the 16 A AC-3 rating, 3-pole configuration, 1 NO auxiliary, and 400…415 V AC coil voltage."},{"question":"What are the key ratings for this contactor?","answer":"Rated operational current is 16 A in AC-3 category at ≤440 V. Motor power ranges from 4 kW at 220…230 V up to 7.5 kW at 380…415 V. Coil voltage is 400…415 V AC. Short-time withstand current is 115 A for 1 second on the power circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K16106N7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K16106N7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}