{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1K16107Y7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1K16107Y7","canonicalUrl":"https://aoctrl.com/schneider/LC1K16107Y7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1K16107Y7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, LC1K16107Y7, 3P, AC-3 ≤440 V 16 A, 1 NO aux., 660...690 V AC coil.","salesMarkdown":"The Schneider Electric LC1K16107Y7 is a TeSys K contactor — a compact 3-pole unit rated 16 A in AC-3 duty at ≤440 V, with a single normally-open auxiliary contact. The coil is wound for 660...690 V AC, so it's built for 690 V line-fed control circuits common in European and export panels. Motor power capability spans 4 kW at 480 V AC up to 7.5 kW at 380...415 V AC, covering a range of voltage standards from 220...230 V through 660...690 V. That's the headline selection number: match your motor's full-load current to the 16 A AC-3 rating, not the kW table, because the kW values assume a specific motor efficiency and power factor. Short-time withstand current (Icw) is 115 A for 1 second on the power circuit — enough to ride through a short-duration fault without welding contacts, provided upstream protection clears within that window. Heat dissipation is 1.3 W, which matters when you stack several contactors in a sealed enclosure. The 45 mm width is three modular units (each 15 mm), so it occupies three slots on a DIN-rail terminal block assembly. Plan your enclosure fill factor accordingly: at 45 mm wide, you can fit about 6 of these per 300 mm of rail. Flame retardance is V1 per UL 94, meaning the housing self-extinguishes within 30 seconds after a flame source is removed — a standard requirement for control panels in most industrial and commercial occupancies. Because it's an active, standard part, sourcing is straightforward: quote against an RFQ for your required quantity. No broker or surplus channel needed — this is a current-production item you'd order through normal supply.","metaTitle":"Schneider LC1K16107Y7 TeSys K Contactor, 3P, 16A AC-3, 690V","metaDescription":"Schneider Electric LC1K16107Y7 TeSys K contactor, 3 poles, 16 A rated operational current in AC-3 at ≤440 V, 1 NO auxiliary contact, 660...690 V AC coil. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","title":"LC1K16107Y7","Height":"58 mm","description":"TeSys K contactor, 3P, AC-3 <= 440 V 16 A, 1 NO aux., 660...690 V AC coil","Product name":"TeSys K","Motor power kW":"4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 4 kW at 220...230 V AC 50/60 Hz 7.5 kW at 380...415 V AC 50/60 Hz","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Heat dissipation":"1.3 W","Range of product":"TeSys K","Device short name":"LC1K","Poles description":"3P","Compatibility code":"LC1K","Device application":"Control","Utilisation category":"AC-3 AC-1","Pole contact composition":"3 NO","Product or component type":"Contactor","[Ie] rated operational current":"16 A at 20 A at 10 MOhm for signalling circuit","[Icw] rated short-time withstand current":"115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f287fc8fb4f2a0d944ad1709c833b703.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC1K16107Y7/tesys-k-contactor-3p-ac3-440-v-16-a-1-no-aux-660-690-v-ac-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to the LC1K16107Y7 in the TeSys family?","answer":"Within the TeSys K range, the closest alternative would be a contactor with the same 16 A AC-3 rating but a different coil voltage — for example, an LC1K1610 with a 230 V AC coil. The physical footprint, auxiliary contact configuration, and breaking capacity are identical; only the coil voltage changes. No pin-compatible drop-in exists for a different coil voltage without rewiring the control circuit."},{"question":"What is the depth of the LC1K16107Y7?","answer":"The depth is 57 mm, measured from the DIN-rail mounting surface to the front of the contactor body. This does not include the coil terminals or auxiliary contact block if fitted."},{"question":"What compliance documentation is available for the LC1K16107Y7?","answer":"The part carries UL 94 V1 flame retardance certification. Standard Schneider TeSys K contactors are typically UL, CSA, and CE marked, but specific approval markings for this order code should be verified against the nameplate or Schneider's compliance database."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1K16107Y7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1K16107Y7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}