{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2D1150046Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2D1150046Q7","canonicalUrl":"https://aoctrl.com/schneider/LC2D1150046Q7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2D1150046Q7","rawCanonicalId":null},"summary":{"shortDescription":"TeSys Deca changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 200 A - 380 V AC coil","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"148 mm","Range":"TeSys","Width":"334 mm","Height":"158 mm","Standards":"CSA C22.2 No 60947-4-1 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.4","Front cover":"With","Product name":"TeSys Deca","Operating time":"20...50 ms closing 6...20 ms opening","Coil technology":"Built-in bidirectional peak limiting diode suppressor","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"mature","Flame retardance":"V1 conforming to UL 94","Heat dissipation":"3...8 W at 50/60 Hz","Mounting support":"Plate Rail","Pollution degree":"3","Average impedance":"0.6 mOhm - Ith 200 A 50 Hz for power circuit","Device short name":"LC2D","Interlocking type":"Mechanical","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 Power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8 Power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8","Climatic withstand":"conforming to IACS E10","Inrush power in VA":"280...350 VA 60 Hz cos phi 0.8 (at 20 °C) 280...350 VA 50 Hz cos phi 0.8 (at 20 °C)","Operating altitude":"0...3000 m","Device presentation":"Preassembled with reversing power busbar","Control circuit type":"AC at 50/60 Hz","Overvoltage category":"III","Protective treatment":"TH conforming to IEC 60068-2-30","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Electrical durability":"0.8 Mcycles 200 A AC-1 at Ue <= 440 V","Mechanical durability":"8000000 cycles","Mechanical robustness":"Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms","Associated fuse rating":"250 A gG at 200 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"1200 cyc/h 60 °C","Connections - terminals":"Control circuit: lugs-ring terminals (external diameter: 8 mm) Power circuit: lugs-ring terminals (external diameter: 25 mm) Power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm","IP degree of protection":"IP20 front face conforming to IEC 60529","Rated breaking capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Changeover contactor","Irms rated making capacity":"1260 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"24 W AC-1","[Uc] control circuit voltage":"380 V AC 50/60 Hz","[Ui] rated insulation voltage":"Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.3...0.5 Uc (-40...55 °C):drop-out AC 50/60 Hz 0.8...1.15 Uc (-40...55 °C):operational AC 50/60 Hz","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: Power circuit: <= 460 V DC","Hold-in power consumption in VA":"2...18 VA (at 20 °C) cos phi 0.3 60 Hz 2...18 VA (at 20 °C) cos phi 0.3 50 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"250 A 40 °C - 10 min for power circuit 550 A 40 °C - 1 min for power circuit 950 A 40 °C - 10 s for power circuit 1100 A 40 °C - 1 s for power circuit","[Ith] conventional free air thermal current":"200 A (at 60 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5c7e925bc2c50f7ab580d3cc863fc2b2.pdf","sourceUrl":"https://www.se.com/nl/en/product/LC2D1150046Q7/tesys-deca-changeover-contactor-4p4-no-ac1-440-v-200-a-380-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2D1150046Q7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2D1150046Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2D1150046Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}