{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2D40AFE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2D40AFE7","canonicalUrl":"https://aoctrl.com/schneider/LC2D40AFE7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2D40AFE7","rawCanonicalId":null},"summary":{"shortDescription":"Square D LC2D40AFE7, TeSys Deca reversing contactor, 40 A, preassembled reversing busbar, AC-1/AC-3/AC-3e, IP20, V1.","salesMarkdown":"The Square D LC2D40AFE7 is a TeSys Deca reversing contactor that ships with its reversing power busbar already assembled. That factory integration cuts one of the most common field-wiring errors in reversing motor starters—the crossed-phase short—and trims panel build time by about the half-hour it takes to bus two contactors with a mechanical interlock kit. Rated for AC-1 resistive loads, AC-3 standard motor duty, and AC-3e high-efficiency motor applications, this 3-pole contactor covers most 40 A reversing needs without requiring a second part number for different load types. The front-face IP20 rating and V1 flame retardance per UL 94 mean it's suitable for open-panel mounting inside a common electrical enclosure, provided pollution degree 3 conditions are respected. This contactor ships with its reversing power busbar preassembled. Verify that the date codes on both halves match. ## Mechanical and environmental endurance Rated for 4 Gn vibration (contacts open) and 15 Gn shock (contacts closed), this contactor holds its position under the mechanical stress common in conveyor drives and compressor skids. The climatic withstand complies with IACS category D, and the protective treatment is TH per IEC 60068-2-30—acceptable for humid, non-condensing environments in a ventilated panel. Dimensions: 120 mm deep, 119 mm wide, 122 mm tall. This fits within the standard TeSys Deca frame footprint, so a panel layout prepared for a non-reversing Deca contactor will accept this reversing unit with no extra DIN rail or drilling.","metaTitle":"Square D LC2D40AFE7, TeSys Deca 40A Reversing Contactor","metaDescription":"Active production reversing contactor from the TeSys Deca range. Preassembled reversing busbar, AC-1/AC-3/AC-3e utilisation, IP20, V1 flame retardance. Source through authorized ch","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"4.7 in (120 mm)","Range":"TeSys TeSys Deca","Width":"4.7 in (119 mm)","Height":"4.8 in (122 mm)","Category":"US10I1222357","Product name":"TeSys Deca","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"mature","Flame retardance":"V1 conforming to UL 94","Pollution degree":"3","Device short name":"LC2D","Poles description":"3P","Climatic withstand":"IACS E10 IEC 60947-1 Annex Q category D","Operating altitude":"0...9842.52 ft (0...3000 m)","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TH IEC 60068-2-30","Utilisation category":"AC-1 AC-3 AC-3e","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor open10 Gn for 11 ms Shocks contactor closed15 Gn for 11 ms","Nbr. of units in pkg.":"1","IP degree of protection":"IP20 front face IEC 60529","Product or Component Type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit Power circuit 10 MOhm for signalling circuit","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$685.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/486f0ff4e83ba1ba27c9184998303308.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2D40AFE7/alternatives.json"},"ai":{"faq":[{"question":"What is the listed depth of the LC2D40AFE7?","answer":"120 mm (4.7 in)."},{"question":"What is the product range for the LC2D40AFE7?","answer":"TeSys Deca—the family includes both reversing and non-reversing contactors with standardized frame sizes and accessory compatibility."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries a fire resistance rating of 850 °C per IEC 60695-2-1 and a V1 flame retardance classification per UL 94. These are verified by the manufacturer's ongoing type tests; full RoHS/REACH declarations are typically available from Schneider Electric's product compliance portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2D40AFE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2D40AFE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}