{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2D50G6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2D50G6","canonicalUrl":"https://aoctrl.com/schneider/LC2D50G6","factsUrl":"https://aoctrl.com/api/mcp/products/LC2D50G6","rawCanonicalId":null},"summary":{"shortDescription":"reversing contactor TeSys LC2-D - 3 poles - AC-3 440 V 50 A - coil 120 V AC","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"5.6 in (142 mm)","Width":"6.5 in (165 mm)","Height":"5.2 in (132 mm)","Category":"22357-CTR,TESYS D,OPEN,40-65A AC","Coil type":"Standard","Standards":"CSA C22.2 No 14 EN 60947-4-1 UL 508 IEC 60947-4-1 IEC 60947-5-1 EN 60947-5-1","Assembly style":"Ready assembled","Motor power kW":"15 kW 220...240 V AC 50/60 Hz 22 kW 380...400 V AC 50/60 Hz 25 kW 415 V AC 50/60 Hz 30 kW 440 V AC 50/60 Hz 30 kW 500 V AC 50/60 Hz 33 kW 660...690 V AC 50/60 Hz","Coil technology":"Without built-in bidirectional peak limiting diode suppressor","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"mature","Heat dissipation":"6...10 W at 60 Hz for control circuit","Protective cover":"With","Range of Product":"TeSys D","Shock resistance":"10 gn contactor closed 8 gn contactor opened","Device short name":"LC2D","Interlocking type":"Mechanical","Poles description":"3P","Operating altitude":"9842.52 ft (3000 m) without derating","Control circuit type":"AC","Protective treatment":"TH 3)IEC 60068","Utilisation category":"AC-2 AC-3 AC-4","Vibration resistance":"2 gn 5...300 Hz contactor opened 3 gn 5...300 Hz contactor closed","Contactor application":"Motor control","Nbr. of units in pkg.":"1","Auxiliary contacts type":"Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1","Connections - terminals":"Control circuit 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit 1 0.002...0.05 in² (1...35 mm²)flexible with cable end Power circuit 1 0.002...0.05 in² (1...35 mm²)flexible without cable end Power circuit 1 0.002...0.05 in² (1...35 mm²)solid without cable end Power circuit 2 0.002...0.04 in² (1...25 mm²)flexible with cable end Power circuit 2 0.002...0.04 in² (1...25 mm²)flexible without cable end Power circuit 2 0.002...0.04 in² (1...25 mm²)solid without cable end Power circuit 2 0.002...0.05 in² (1...35 mm²)flexible with cable end Power circuit 2 0.002...0.05 in² (1...35 mm²)flexible without cable end Power circuit 2 0.002...0.05 in² (1...35 mm²)solid without cable end","IP degree of protection":"IP2X IEC 60529 IP2X VDE 0106","Pole contact composition":"3 NO","Product or Component Type":"Reversing contactor","[Uc] control circuit voltage":"120 V AC 60 Hz","Auxiliary contact composition":"1 NO + 1 NC","Control circuit voltage limits":"Drop-out: 0.3...0.6 Uc at 50/60 Hz (at Operational: 0.8...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at 10 MOhm for control circuit","[Ie] rated operational current":"Power circuit 50 A AC AC-3 140 °F (60 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"23...140 °F (-5...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/LC2D50G6/reversing-contactor-tesys-lc2d-3-poles-ac3-440-v-50-a-coil-120-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2D50G6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2D50G6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2D50G6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}