{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2D80004P5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2D80004P5","canonicalUrl":"https://aoctrl.com/schneider/LC2D80004P5","factsUrl":"https://aoctrl.com/api/mcp/products/LC2D80004P5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider LC2D80004P5 Tesys Deca Advanced — now discontinued, supplied from remaining surplus and broker stock.","salesMarkdown":"## Overview The LC2D80004P5 is a Schneider TeSys Deca Advanced changeover contactor with 4 poles, rated for 125 A switching current and a 230 V AC 50 Hz coil. It carries a 1.1 kA breaking capacity and dissipates 6 to 10 W at 50 Hz, with a total power consumption of 20 W. Preassembled with prewired power connections, it mounts on plate or rail and is sealed to IP20. Compliance covers IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Compared to the LC1D40008X6, the LC2D80004P5 doubles the switching current (125 A vs 60 A) and raises the breaking capacity to 1.1 kA versus 800 A at 440 V. The LC2D80004P5 also draws higher coil power (20 W vs 13 W) and uses a 4-pole changeover configuration rather than 2 NO + 2 NC poles.","metaTitle":"Schneider LC2D80004P5 TeSys Deca changeover contactor, 125 A, 4-pole","metaDescription":"Schneider LC2D80004P5 TeSys Deca Advanced changeover contactor: 4-pole, 125 A switching, 230 V AC 50 Hz coil, 1.1 kA breaking capacity, 20 W consumption.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"6.2 in (158 mm)","Range":"TeSys","Width":"8.1 in (207 mm)","Height":"5 in (127 mm)","Category":"22359-CTR,TESYS D,OPEN,80-150A AC&DC","Standards":"CSA C22.2 No 60947-4-1 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.4","Front cover":"Without","Product name":"TeSys Deca","Operating time":"20...35 ms closing 6...20 ms opening","Coil technology":"Without built-in suppressor module","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"mature","Flame retardance":"V1 conforming to UL 94","Heat dissipation":"6...10 W 50 Hz","Mounting Support":"Plate Rail","Pollution degree":"3","Average impedance":"0.8 mOhm - Ith 125 A 50 Hz for power circuit","Device short name":"LC2D","Interlocking type":"Mechanical","Poles description":"4P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2","Climatic withstand":"IACS E10","Inrush power in VA":"200 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))","Operating altitude":"0...9842.52 ft (0...3000 m)","Device presentation":"Preassembled, with prewired power connections","Control circuit type":"AC 50 Hz","Overvoltage category":"III","Protective treatment":"TH IEC 60068-2-30","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Electrical durability":"0.8 Mcycles 125 A AC-1 <= 690 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Shocks contactor open8 Gn for 11 ms Vibrations contactor closed3 Gn, 5...300 Hz Shocks contactor closed10 Gn for 11 ms","Nbr. of units in pkg.":"1","Associated fuse rating":"200 A gG at 160 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"3600 cyc/h 140 °F (60 °C)","Connections - terminals":"Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid Control circuit screw clamp terminals 1 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Power circuit connector 1 0.006...0.08 in² (4...50 mm²)flexible without cable end Power circuit connector 2 0.006...0.04 in² (4...25 mm²)flexible without cable end Power circuit connector 1 0.006...0.08 in² (4...50 mm²)flexible with cable end Power circuit connector 2 0.006...0.02 in² (4...16 mm²)flexible with cable end Power circuit connector 1 0.006...0.08 in² (4...50 mm²)solid Power circuit connector 2 0.006...0.04 in² (4...25 mm²)solid","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Changeover contactor","Irms rated making capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"12.5 W AC-1","[Uc] control circuit voltage":"230 V AC 50 Hz","[Ui] rated insulation voltage":"Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1","Control circuit voltage limits":"0.3...0.6 Uc (-40...131 °F (-40...55 °C)):drop-out AC 50 Hz 0.85...1.1 Uc (-40...131 °F (-40...55 °C)):operational AC 50 Hz","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"125 A (at 80 A (at 80 A (at 55 A (at <140 °F (60 °C)) at <= 400 V AC AC-4 for power circuit","[Ue] rated operational voltage":"Power circuit Power circuit <= 300 V DC","Hold-in power consumption in VA":"20 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947","[Icw] rated short-time withstand current":"135 A 104 °F (40 °C) - 10 min for power circuit 320 A 104 °F (40 °C) - 1 min for power circuit 640 A 104 °F (40 °C) - 10 s for power circuit 990 A 104 °F (40 °C) - 1 s for power circuit","[Ith] conventional free air thermal current":"125 A (at 140 °F (60 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,370.38","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a05e86a94e9b3bb4249f582facb0c368.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2D80004P5/changeover-contactor-tesys-deca-4p4no-ac1-440v-125a-230v-ac-50-60hz-coil-screw-clamp-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2D80004P5/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2D80004P5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2D80004P5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}