{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K06015R7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K06015R7","canonicalUrl":"https://aoctrl.com/schneider/LC2K06015R7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K06015R7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K06015R7, 3P, AC-3 <=440 V 6 A, 1 NC, 440 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"Rated AC-3 <=440 V 6 A, it switches three-phase squirrel-cage motors up to that current in reversing duty. The 440 V AC coil matches standard European control voltages. AC-3 is the utilisation category for starting and stopping squirrel-cage motors under load — the 6 A rating at <=440 V is the current the contactor can break reliably during normal motor starts. AC-4 (also listed) covers inching and plugging, where the contactor interrupts locked-rotor current, so this part handles both reversing and jogging cycles without derating. IP20 finger-safe terminals suit enclosed panel mounting, not open washdown areas. Preassembled with reversing power busbar means no separate busbar kit to order and no risk of wiring the interlock wrong in the field. The 1 NC auxiliary contact provides a positive feedback path for the control logic to confirm the contactor state.","metaTitle":"TeSys K LC2K06015R7 reversing contactor, 3P, AC-3 6 A at 440","metaDescription":"TeSys K reversing contactor LC2K06015R7, 3P, AC-3 <=440 V 6 A, 1 NC, 440 V AC coil. Active production. IP20. Motor control. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K06015R7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NC, 440 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/13b2323b1128205674557c0d2a781acb.pdf","sourceUrl":"https://www.se.com/in/en/product/LC2K06015R7/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-nc-440-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"3-pole, AC-3 <=440 V 6 A motor rating, 440 V AC coil, 1 NC auxiliary contact. IP20. Operating temperature -25 to 50 °C, no derating to 2000 m altitude."},{"question":"What compliance documentation does Schneider Electric provide for LC2K06015R7?","answer":"Flame retardance V1 per UL 94, plus compliance with NF F 16-101 and NF F 16-102 (French railway standards). Protective treatment per IEC 60068 and DIN 50016 (tropical climate). Shock and vibration tested per IEC 60068-2-27 and IEC 60068-2-6."},{"question":"What is the closest alternative to LC2K06015R7 in the TeSys K family?","answer":"Within the same TeSys K family, the single-direction contactor (e.g., LC1K0601) shares the same coil voltage and pole configuration but lacks the reversing busbar and mechanical interlock. For a reversing pair built from two singles, you would add a separate reversing busbar kit and external interlock — the LC2K06015R7 is the factory-assembled version that saves panel space and wiring time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K06015R7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K06015R7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}