{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K0601B7TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K0601B7TQ","canonicalUrl":"https://aoctrl.com/schneider/LC2K0601B7TQ","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K0601B7TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NC, 24 V AC coil, TQ package, preassembled with reversing power busbar.","salesMarkdown":"The LC2K0601B7TQ is a TeSys K reversing contactor from Schneider Electric — a 3-pole device rated AC-3 at 6 A up to 440 V, with a 24 V AC coil and one NC auxiliary contact. That means less panel wiring and a smaller chance of cross-connection errors during build. The AC-3 rating at 6 A is the motor-switching figure — it covers starting and disconnecting squirrel-cage motors under load. For a reversing contactor, AC-4 capability matters because reversing often involves counter-torque braking. The coil is 24 V AC — common in North American control transformers and European 24 V AC control circuits. IP20 finger protection (VDE 0106) means it's safe for open-panel mounting but not for washdown environments. This is a panel-mount reversing contactor sized for motor control centers and industrial control panels. The dimensions — 2.2 in deep, 3.5 in wide, 2.3 in tall — fit standard 35 mm DIN rail or direct panel mounting. The preassembled busbar saves the step of wiring a separate reversing kit. Altitude rating is 2000 m without derating, so it's fine for most sites outside high-altitude installations. Flame retardance is V1 per UL 94, with additional compliance to NF F 16-101 and NF F 16-102 (railway fire behavior standards). Protective treatment follows TC IEC 60068 and TC DIN 50016 for environmental resistance. The IP20 rating meets VDE 0106 for finger protection. These approvals cover the regulatory requirements for most industrial control panels in North America and Europe.","metaTitle":"TeSys K LC2K0601B7TQ reversing contactor, 3P, AC-3 6 A, 24 V","metaDescription":"TeSys K LC2K0601B7TQ reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NC, 24 V AC coil. Active production. IP20. Preassembled with reversing power busbar. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"2.2 in (57 mm)","Range":"TeSys","Width":"3.5 in (90 mm)","title":"LC2K0601B7TQ","Height":"2.3 in (58 mm)","Category":"22327-CTR,K-LINE,AC,OPEN,REV","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NC, 24 V AC, TQ pkg","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device Application":"Control","Operating altitude":"6561.68 ft (2000 m) without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC IEC 60068 TC DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6","Nbr. of units in pkg.":"1","IP degree of protection":"IP20 VDE 0106","Product or Component Type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit 690 V AC 50/60 Hz Signalling circuit 10 MOhm for signalling circuit","Ambient Air Temperature for Storage":"-58...176 °F (-50...80 °C)","Ambient Air Temperature for Operation":"-13...122 °F (-25...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c76bad62c5483ba6e5d9d84a871c4cd5.pdf","sourceUrl":"https://www.se.com/nl/en/product/LC2K0601B7TQ/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-nc-24-v-ac-tq-pkg/"},"ai":{"faq":[{"question":"What is the closest alternative to LC2K0601B7TQ in the TeSys K family?","answer":"The closest alternative would be a standard (non-reversing) TeSys K contactor with the same coil voltage and pole configuration, paired with a separate reversing mechanical interlock kit. The LC2K0601B7TQ is unique in being preassembled with the reversing busbar, so the main difference is assembly labor and panel wiring time."},{"question":"What is the depth of LC2K0601B7TQ?","answer":"The depth is 2.2 in (57 mm)."},{"question":"What compliance documentation is available for LC2K0601B7TQ?","answer":"The contactor carries UL 94 V1 flame retardance, NF F 16-101 and NF F 16-102 railway fire compliance, and IP20 per VDE 0106. Protective treatment follows IEC 60068 and DIN 50016. Standard Schneider Electric declarations of conformity (CE, UKCA) are available through the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K0601B7TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K0601B7TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}