{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K0601K72","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K0601K72","canonicalUrl":"https://aoctrl.com/schneider/LC2K0601K72","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K0601K72","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 6 A, 1 NC, 100 V AC coil, IP20.","salesMarkdown":"It switches a 3-phase motor up to 6 A at ≤440 V AC (AC-3), with a 100 V AC coil. The 1 NC auxiliary contact provides a feedback path for the reversing interlock or status monitoring. Rated operational voltage on the power circuit is 690 V AC 50/60 Hz, so it can handle 400 V and 480 V line supplies without derating up to 2000 m altitude. The AC-3 rating (6 A at ≤440 V) governs motor switching — that is the current it can make and break across a standard induction motor load. AC-4 covers plugging and inching duty, where the contactor sees higher electrical wear. The IP20 finger-safe enclosure (VDE 0106) suits panel-mount installations where the contactor is behind a cabinet door. ## Mechanical and environmental tolerance Rated for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6: the contactor holds closed through 10 Gn on Y and Z axes, 6 Gn on X axis (11 ms half-sine). Vibration resistance is 4 Gn closed, 2 Gn open across 5–300 Hz. Storage temperature spans -50 to 80 °C; operating ambient is -25 to 50 °C. The protective treatment conforms to IEC 60068 and DIN 50016 for damp heat and corrosive atmospheres. Depth 57 mm, width 90 mm, height 58 mm. The 1 NC auxiliary is wired into the reversing interlock logic.","metaTitle":"TeSys K LC2K0601K72 reversing contactor, 3P, 6 A AC-3, 100 V","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 ≤440 V 6 A, 1 NC, 100 V AC coil. Sourced to order against RFQ. IP20, 690 V AC rated.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/838f54353be138ff1ca58f0e93a1102c.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC2K0601K72/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-nc-100-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K0601K72/alternatives.json"},"ai":{"faq":[{"question":"What replaces LC2K0601K72?","answer":"No official successor order code is provided in the lifecycle record. For a drop-in replacement, an RFQ is needed to cross-reference the ratings (3P, AC-3 6 A at ≤440 V, 100 V AC coil, 1 NC) against current TeSys K or TeSys Deca series contactors."},{"question":"What compliance documentation is available for this part?","answer":"The part carries flame retardance V1 per UL 94, conforms to NF F 16-101/102 for rail fire/smoke requirements, and protective treatment per IEC 60068 and DIN 50016. RoHS, REACH, and UL declarations are provided at time of order."},{"question":"What is the depth of LC2K0601K72?","answer":"57 mm."},{"question":"What series does LC2K0601K72 belong to?","answer":"TeSys K."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K0601K72","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K0601K72 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}