{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K0601W7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K0601W7","canonicalUrl":"https://aoctrl.com/schneider/LC2K0601W7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K0601W7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 6 A, 1 NC, 256 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"Rated for AC-3 and AC-4 utilization categories, it switches motor loads up to 6 A at 440 V AC — the AC-3 rating governs the motor starting current, while AC-4 covers plugging or inching duty where the contactor makes and breaks stalled-rotor current. The 256 V AC coil is the control voltage you need to supply; the contactor pulls in cleanly on that nominal and drops out reliably below the release threshold. Built into the TeSys K family, this reversing contactor is sized for control panels where direction reversal of a small motor (conveyor, fan, actuator) is required. The IP20 finger-safe enclosure meets VDE 0106, so it's suitable for enclosed panel environments where accidental contact with live parts must be prevented.","metaTitle":"TeSys K LC2K0601W7 reversing contactor, 3P, 6 A AC-3, 256 V","metaDescription":"TeSys K LC2K0601W7 reversing contactor, 3P, AC-3 <=440 V 6 A, 1 NC, 256 V AC coil. Active production. IP20. Preassembled reversing busbar. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC2K0601W7/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-nc-256-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K0601W7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the LC2K0601W7 in the TeSys K family?","answer":"Within the TeSys K family, the closest peer would be a reversing contactor with the same pole configuration and coil voltage but a different auxiliary contact arrangement. The LC2K0601W7 carries 1 NC auxiliary; if you need 1 NO instead, the sibling with that contact configuration is the direct swap. Both share the same footprint, busbar, and AC-3 rating."},{"question":"What is the depth of the LC2K0601W7?","answer":"The depth is 57 mm, with a width of 90 mm and height of 58 mm."},{"question":"What compliance documentation is available for the LC2K0601W7?","answer":"The part carries flame retardance V1 per UL 94, plus compliance with NF F 16-101 and NF F 16-102 for railway fire-smoke. It is IP20 per VDE 0106. For RoHS, REACH, and full UL/IEC certification, the manufacturer's declaration pack is available through the standard documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K0601W7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K0601W7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}