{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K06103F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K06103F7","canonicalUrl":"https://aoctrl.com/schneider/LC2K06103F7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K06103F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NO, 110 V AC coil, 57 mm depth.","salesMarkdown":"## What you're sourcing The LC2K06103F7 is a TeSys K reversing contactor from Schneider Electric — three poles, rated AC-3 at 6 A up to 440 V, with a 110 V AC coil and one normally open auxiliary contact. It ships preassembled with the reversing power busbar, so you skip the mechanical interlock wiring step on the panel bench. The IP20 finger-safe housing (VDE 0106) suits it for enclosed control panels where live parts aren't exposed during normal operation. The AC-3 rating at 6 A / 440 V is the motor-switching duty — that's the figure that decides whether it handles your reversing starter for a small conveyor or pump motor. The 690 V AC operational voltage on the power circuit gives headroom for 480 V or 600 V line supplies, though the AC-3 current must be derated above 440 V per the manufacturer's curve. The 110 V AC coil is standard across many panel designs — verify your control transformer output matches. Coil holding voltage is within the 0.85–1.1 x Uc range typical for this class; dropout occurs reliably below the minimum threshold, avoiding welded contacts on brownout.","metaTitle":"Schneider TeSys K LC2K06103F7 Reversing Contactor, 110 V AC","metaDescription":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NO, 110 V AC coil. Active lifecycle. IP20. 57 mm depth. Order LC2K06103F7.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K06103F7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NO, 110 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/53e4b10d4352986788a9ba9710541af6.pdf","sourceUrl":"https://www.se.com/nl/en/product/LC2K06103F7/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-no-110-v-ac-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to LC2K06103F7 in the TeSys K family?","answer":"The non-reversing equivalent is the LC1K06103F7 (same coil, same AC-3 rating, same 1 NO auxiliary). The reversing busbar and mechanical interlock are what distinguish the LC2K version — if your design uses an external interlock, the LC1K pair with a separate reversing kit may be a functional alternative, but the LC2K06103F7 is the pre-assembled factory solution."},{"question":"What compliance documentation is available for LC2K06103F7?","answer":"The part carries V1 flame retardance per UL 94, and meets NF F 16-101 and NF F 16-102 for railway fire-smoke requirements. Protective treatment conforms to IEC 60068 and DIN 50016. The IP20 rating is per VDE 0106. Standard Schneider declarations (RoHS, REACH) are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K06103F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K06103F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}