{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K06103L7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K06103L7","canonicalUrl":"https://aoctrl.com/schneider/LC2K06103L7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K06103L7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 6 A, 1 NO, 200-208 VAC coil, 57 mm depth, 90 mm width, 58 mm height.","salesMarkdown":"It carries three NO power poles and one NO auxiliary contact, with a 200-208 VAC coil. The AC-3 rating at 6 A, 440 V is the motor-switching duty — starting and stopping a squirrel-cage induction motor under load. That current figure governs the real-world motor size this contactor can handle; a 6 A AC-3 rating typically corresponds to a 2.2 kW (3 HP) motor at 400 V three-phase. The 200-208 VAC coil is specific — not the more common 230 V or 240 V control voltage common in European panels. If the control transformer in the cabinet delivers 208 V phase-to-phase (common in North American 208Y/120 V systems), this coil is a direct fit. If the control voltage is 230 V or 240 V, the coil will overheat or fail to hold in, so the coil voltage must match the control circuit exactly.","metaTitle":"Schneider Electric LC2K06103L7 TeSys K Reversing Contactor,","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 <=440 V 6 A, 1 NO, 200-208 VAC coil. Sourced to order against RFQ. Depth 57 mm, width 90 mm, height 58 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/538f16560f61fe1fc2b0ec9d5ac2cf69.pdf","sourceUrl":"https://www.se.com/in/en/product/LC2K06103L7/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-no-200-208-vac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K06103L7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC2K06103L7?","answer":"It is a 3-pole reversing contactor rated AC-3 at 6 A, 440 V, with a 200-208 VAC coil. It carries one NO auxiliary contact and is preassembled with a reversing power busbar. Dimensions are 90 mm wide, 58 mm tall, 57 mm deep."},{"question":"What compliance documentation is available for this part?","answer":"The part carries UL 94 V1 flame retardance rating and conforms to NF F 16-101/102 for railway fire behaviour. Protective treatment complies with IEC 60068 and DIN 50016. No RoHS or REACH statement is recorded in this listing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K06103L7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K06103L7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}