{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K06103M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K06103M7","canonicalUrl":"https://aoctrl.com/schneider/LC2K06103M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K06103M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K06103M7, 3-pole, AC-3 ≤440 V 6 A, 1 N.O. auxiliary, 220…230 VAC coil, IP20 finger-safe.","salesMarkdown":"It's rated AC-3 at 6 A up to 440 V, which means it's sized for small three-phase motors (pumps, fans, conveyors) where you need forward/reverse control. The 220…230 VAC coil matches standard control voltages in European panels. AC-3 at 6 A is the motor-switching rating — that's the one that decides if it handles your load. AC-4 is also listed, covering inching/jogging duty where the contactor breaks stalled-rotor current. The 6 A AC-3 figure is conservative for a reversing contactor this size; it reflects the thermal limits of the compact 57 mm deep × 90 mm wide body. If your motor FLA exceeds 6 A at 440 V, step up to the next TeSys K frame. The 57 mm depth × 58 mm height × 90 mm width fits standard DIN-rail enclosures; the preassembled busbar saves a few minutes on the rail. Ambient range -25…50 °C covers most control cabinets without derating; storage from -50…80 °C. Operating altitude 2000 m without derating — fine for most sites, but above that you'll need to reduce current.","metaTitle":"Schneider TeSys K LC2K06103M7 Reversing Contactor, 3P, 6A AC","metaDescription":"Active-production TeSys K reversing contactor from Schneider, 3 poles, AC-3 rated 6A at ≤440V, 220-230VAC coil, IP20. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K06103M7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NO, 220...230 VAC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/af4ec09338e2a9e7b67b58e084959452.pdf","sourceUrl":"https://www.se.com/nl/en/product/LC2K06103M7/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-no-220-230-vac-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to the LC2K06103M7 in the TeSys K family?","answer":"Within the TeSys K range, the LC2K series uses the same physical footprint and busbar system, but each variant is defined by its current rating and coil voltage. There is no single pin-compatible drop-in; you would select the LC2K order code that matches your required AC-3 current and control voltage."},{"question":"What are the key dimensions of the LC2K06103M7?","answer":"Depth is 57 mm, width is 90 mm, height is 58 mm. These dimensions fit standard DIN-rail enclosures."},{"question":"What compliance documentation is available for this contactor?","answer":"The part carries V1 flame retardance per UL 94, and IP20 protection per VDE 0106. It is part of the Schneider TeSys range, which typically supports RoHS and REACH declarations through the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K06103M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K06103M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}