{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K06103U7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K06103U7","canonicalUrl":"https://aoctrl.com/schneider/LC2K06103U7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K06103U7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K06103U7, 3P, AC-3 <=440V 6A, 1 NO, 230-240VAC coil, IP20.","salesMarkdown":"The Schneider Electric TeSys K LC2K06103U7 is a 3-pole reversing contactor rated for motor control in AC-3 and AC-4 utilisation categories. The contactor ships preassembled with the reversing power busbar, so the mechanical interlock and main power wiring between the two contactor halves is already in place, saving panel build time. The coil is 230-240 VAC, so it drops straight into a 240 V control transformer secondary without an extra buck-boost. Rated operational voltage on the power circuit is 690 V AC 50/60 Hz, giving headroom for 480 V or 600 V line applications, though the motor current rating must be derated above 440 V per the manufacturer's curve. For higher ambient or altitude above 2000 m, derate the continuous current accordingly. The contactor carries V1 flame retardance per UL 94 and meets NF F 16-101 / NF F 16-102 for railway fire-smoke-toxicity requirements. Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance. Mechanical robustness is specified for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6, with the contactor withstanding 10-15 Gn shocks in the closed position and 4 Gn vibration at 5-300 Hz.","metaTitle":"Schneider TeSys K LC2K06103U7 Reversing Contactor, 3P, 6A AC","metaDescription":"Schneider Electric TeSys K reversing contactor LC2K06103U7, 3P, 6A at <=440V AC-3, 230-240VAC coil, IP20. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC2K06103U7/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-no-230-240-vac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K06103U7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LC2K06103U7 in the TeSys K family?","answer":"Within the TeSys K reversing contactor range, the LC2K06103U7 is defined by its 6 A AC-3 rating and 230-240 VAC coil. The closest sibling would share the same frame and pole count but differ in coil voltage (e.g., 24 VAC or 110 VAC variants) or current rating (e.g., 9 A frame). The mechanical interlock and busbar assembly are common across the series, so swapping to a different coil voltage variant is a direct fit for the same panel layout."},{"question":"What compliance documentation does Schneider provide for LC2K06103U7?","answer":"The contactor is UL 94 V1 rated for flame retardance and meets NF F 16-101/102 for railway fire safety. Protective treatment complies with IEC 60068 and DIN 50016. Shock and vibration testing follows IEC 60068-2-27 and IEC 60068-2-6. Standard Schneider declarations (CE, UKCA, EAC) apply per the TeSys K series documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K06103U7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K06103U7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}