{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K0610FE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K0610FE7","canonicalUrl":"https://aoctrl.com/schneider/LC2K0610FE7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K0610FE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K0610FE7, 3-pole, AC-3/AC-3e 6A at ≤440V, 1NO auxiliary contact, 115V AC coil, preassembled with reversing power busbar.","salesMarkdown":"The Schneider Electric LC2K0610FE7 is a reversing contactor from the TeSys K series, designed for motor control in AC-3, AC-3e, and AC-4 utilisation categories. The 115 V AC coil operates the main poles and the single normally-open auxiliary contact. The IP20 finger-safe enclosure (VDE 0106) suits installation inside a control cabinet. ## Sourcing reality — lifecycle status Because this part is obsolete, any replacement requires a full requalification — the TeSys K form factor and mounting footprint differ from current TeSys Deca or TeSys Giga series. There is no direct pin-compatible drop-in from the current catalogue. The AC-3 rating of 6 A at ≤440 V governs motor switching capability. Mechanical robustness ratings show the contactor withstands 10 Gn shocks on Y and Z axes when closed, and 4 Gn vibration at 5–300 Hz when closed — sufficient for most industrial machinery but worth checking against high-shock applications like stamping presses or crushers.","metaTitle":"Schneider LC2K0610FE7 TeSys K Reversing Contactor, 3P, 6A AC","metaDescription":"Obsolete reversing contactor from TeSys K series. 3-pole, 6A AC-3/AC-3e, 1NO auxiliary, 115V AC coil. Preassembled reversing busbar. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/98c3bd332d6ae5e85d13734b094a06f2.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2K0610FE7/reversing-contactor-tesys-k-3p-ac3-ac3e-440v-6a-1no-115v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K0610FE7/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC2K0610FE7?","answer":"There is no direct pin-compatible drop-in replacement from the current Schneider catalogue. The TeSys K series is discontinued; moving to a current TeSys Deca or TeSys Giga reversing contactor will require panel rework and requalification of the BOM line."},{"question":"What are the key ratings for this contactor?","answer":"It is a 3-pole reversing contactor rated 6 A in AC-3 duty at ≤440 V, with a 115 V AC coil and one normally-open auxiliary contact. It is preassembled with a reversing power busbar."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K0610FE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K0610FE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}