{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K09015P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K09015P7","canonicalUrl":"https://aoctrl.com/schneider/LC2K09015P7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K09015P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K09015P7, 3-pole, 9 A AC-3/AC-3e at 440 V, 1 NC auxiliary, 230 V AC coil, solder pin terminals, preassembled with reversing power busbar.","salesMarkdown":"## What this reversing contactor is — and why it saves panel time The LC2K09015P7 is a TeSys K reversing contactor — a 3-pole unit rated 9 A in AC-3/AC-3e duty at 440 V, with a 230 V AC coil and one NC auxiliary contact. It comes preassembled with the reversing power busbar, which means it lands on the DIN rail as a single mechanical and electrical unit rather than two separate contactors you wire together on site. For a panel builder or field tech swapping a failed reversing starter, that cuts install time to minutes. The AC-3 and AC-3e rating at 440 V is the one that matters for motor starting — 9 A covers a 3 kW induction motor on a 400 V line. AC-4 covers plugging and inching duty, so it handles reversing applications where the motor is switched while still spinning. The 230 V AC coil is standard for North American and European control voltages — pulls in reliably down to about 0.85 x nominal. Solder pin terminals suit a PCB or a pre-wired control board, not field wiring; if you're landing field cables, you'll want the screw-clamp variant in the same TeSys K family. ## Where it goes — the deployment context This is a DIN-rail reversing contactor sized for a panel — the 57 mm depth and 90 mm width fit a standard 35 mm rail with room for a motor circuit breaker and overload relay alongside it. The preassembled reversing busbar means the mechanical interlock and power cross-wiring are already done; you just land the line and load wires, wire the coil, and connect the NC aux into your safety or feedback circuit. It's a control contactor — used for switching motor loads in conveyors, pumps, fans, and compressors where forward/reverse operation is needed. The AC-4 rating confirms it's suited for frequent reversals, not just occasional direction changes. For volume or contract pricing, send the order code and target quantity; we'll confirm lead time from the factory pipeline.","metaTitle":"TeSys K LC2K09015P7 Reversing Contactor, 9A AC-3, 230V AC Co","metaDescription":"Active-production reversing contactor, TeSys K series, 3P, 9A at 440V AC-3/AC-3e, 1NC aux, 230V AC coil, solder pins. IP20, preassembled with reversing busbar. RFQ for volume.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K09015P7","Height":"58 mm","description":"reversing Contactor, TeSys K, 3P, AC-3/AC-3e,440V 9A, 1NC, 230V AC coil,solder pins","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-4 AC-3 AC-3e","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$123.17","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d2f82fc323617d0056dcdea327c0eec8.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2K09015P7/reversing-contactor-tesys-k-3p-ac3-ac3e440v-9a-1nc-230v-ac-coilsolder-pins/"},"ai":{"faq":[{"question":"What is the depth of the LC2K09015P7?","answer":"The depth is 57 mm, with a width of 90 mm and height of 58 mm."},{"question":"What compliance documentation is available for this part?","answer":"The part carries V1 flame retardance per UL 94, IP20 per VDE 0106, and shock/vibration robustness per IEC 60068-2-27 and IEC 60068-2-6. Protective treatment conforms to IEC 60068 and DIN 50016. Standard Schneider documentation includes the RoHS and REACH declarations; UL and CSA file numbers are listed on the product certificate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K09015P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K09015P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}