{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K0901P72","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K0901P72","canonicalUrl":"https://aoctrl.com/schneider/LC2K0901P72","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K0901P72","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K0901P72, 3P, AC-3 9 A at 440 V, 1 NC, 230 V AC coil, IP20.","salesMarkdown":"The 230 V AC coil pulls in the main poles; the built-in 1 NC auxiliary contact provides electrical interlocking to prevent both contactors from closing simultaneously. AC-1 rating covers resistive loads at the same current; The 3 NO power poles switch the motor lines; the 1 NC auxiliary is wired into the coil circuit of the opposite contactor to enforce mechanical and electrical interlock. Vibration resistance of 4 Gn closed and 2 Gn open (5–300 Hz) means it holds in on a typical industrial panel wall without nuisance dropout. Shock ratings of 10–15 Gn on the Y and Z axes closed, 6–10 Gn open, cover most machine-mounted installations.","metaTitle":"TeSys K LC2K0901P72 reversing contactor, 9 A AC-3, 230 VAC c","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 9 A at 440 V, 1 NC aux, 230 VAC coil. Sourced to order against RFQ via independent channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9debe5b4100d69f471c12ceb3a93818f.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2K0901P72/tesys-k-reversing-contactor-3p-ac3-440-v-9-a-1-nc-230-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K0901P72/alternatives.json"},"ai":{"faq":[{"question":"What replaces LC2K0901P72?","answer":"No official successor order code is recorded. For a direct replacement, you would need to evaluate current TeSys K or TeSys Deca series contactors with matching pole count, coil voltage, and auxiliary configuration — but no pin-compatible drop-in is documented."},{"question":"What are the key ratings for this contactor?","answer":"AC-3 motor-switching current of 9 A at 440 V, 230 V AC coil, 3 NO power poles plus 1 NC auxiliary contact. IP20 finger-safe enclosure. Operates from -25 to 50 °C ambient."},{"question":"What compliance documentation is available?","answer":"The part carries V1 flame retardance per UL 94 and conforms to NF F 16-101 and NF F 16-102 for railway fire-smoke-toxicity. Protective treatment conforms to IEC 60068 and DIN 50016. IP20 per VDE 0106."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K0901P72","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K0901P72 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}