{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K0901V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K0901V7","canonicalUrl":"https://aoctrl.com/schneider/LC2K0901V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K0901V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 9 A, 1 NC, 400 V AC coil, preassembled with reversing power busbar, IP20.","salesMarkdown":"Rated for AC-3 duty at 9 A up to 440 V, it handles small three-phase motors (typically up to 2.2 kW at 400 V) for forward-reverse applications like conveyor drives, pump direction changes, or actuator control. The 400 V AC coil matches standard European control voltages. AC-1 (resistive load) and AC-4 (plugging/inching) ratings are also listed, but AC-3 is the one that decides fit for standard motor control. The 400 V AC coil draws from the control transformer; verify your control circuit voltage matches exactly, because a coil rated for 400 V AC will not pull in reliably at 230 V and will overheat at 480 V. The unit is rated to operate without derating up to 2000 m altitude. Shock and vibration ratings per IEC 60068-2-27 and IEC 60068-2-6 are documented: the closed contactor withstands 10 Gn on the X axis and 15 Gn on Y and Z axes for 11 ms shocks, with vibration resistance at 4 Gn from 5 to 300 Hz.","metaTitle":"Schneider LC2K0901V7 TeSys K Reversing Contactor, 9A AC-3, 4","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 9A at 440V, 400V AC coil, 1 NC. Sourced to order against RFQ. IP20, DIN-rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5a883777fedd1db418f0f4b2ad737748.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2K0901V7/tesys-k-reversing-contactor-3p-ac3-440-v-9-a-1-nc-400-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K0901V7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The critical rating is AC-3 motor-switching current: 9 A at 440 V. The coil is 400 V AC. The contactor is 3-pole with 1 NC auxiliary contact. Dimensions are 90 mm wide × 58 mm high × 57 mm deep for DIN-rail mounting."},{"question":"What approvals does this part carry?","answer":"The LC2K0901V7 carries IP20 finger-safe protection per VDE 0106, and flame retardance rated V1 per UL 94. It also meets NF F 16-101 and NF F 16-102 requirements for railway rolling stock fire behaviour. The protective treatment conforms to IEC 60068 and DIN 50016 for tropical environments."},{"question":"How do I source this obsolete part?","answer":"Since it is obsolete, the only channel is surplus or broker inventory. Submit an RFQ with your target quantity and we will check availability across our sourcing network. There is no standard lead time or stock level we can guarantee."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K0901V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K0901V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}