{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K0910D72","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K0910D72","canonicalUrl":"https://aoctrl.com/schneider/LC2K0910D72","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K0910D72","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K0910D72, 3P, AC-3 9 A at 440 V, 36 V AC coil, IP20, preassembled with reversing power busbar.","salesMarkdown":"The Schneider Electric TeSys K LC2K0910D72 is a 3-pole reversing contactor rated for AC-3 duty at 9 A up to 440 V, with a 36 V AC coil. The reversing contactor is preassembled with the reversing power busbar, which saves panel wiring time and reduces the chance of phase-reversal errors during commissioning. The AC-1 rating (resistive load) and AC-4 rating (inching/plugging duty) are also listed, so the contactor can handle lamp or heater loads and frequent reversing applications within its thermal limits. Rated operational voltage on the power circuit is 690 V AC 50/60 Hz, giving headroom for 400 V or 480 V systems. This reversing contactor is sized for motor control applications up to 9 A AC-3 — typically small conveyors, fans, pumps, or valve actuators that require forward/reverse operation. The 36 V AC coil is common in control transformer circuits or PLC-driven contactor banks where low-voltage control is preferred for safety. The contactor measures 90 mm wide by 58 mm high by 57 mm deep, fitting standard DIN-rail or panel-mount layouts. Operating temperature range is -25 to 50 °C, with storage from -50 to 80 °C, and no derating required up to 2000 m altitude. The contactor carries the standard Schneider warranty and is supported by the full TeSys K accessory range (auxiliary contact blocks, coil suppressors, mechanical interlocks).","metaTitle":"Schneider TeSys K LC2K0910D72 reversing contactor, 3P, 9 A A","metaDescription":"TeSys K reversing contactor LC2K0910D72, 3P, AC-3 9 A at 440 V, 36 VAC coil, IP20. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K0910D72","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 9 A, 1 NO, 36 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-1 AC-3 AC-3e","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cfa573ece1d9e8e65930185c9147639d.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2K0910D72/tesys-k-reversing-contactor-3p-ac3-440-v-9-a-1-no-36-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings I need to verify for fit?","answer":"The critical rating is AC-3 9 A at 440 V for motor switching. The coil is 36 V AC. The contactor is 3-pole, IP20, and preassembled with the reversing busbar. Operating temperature range is -25 to 50 °C."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries VDE 0106 (IP20), UL 94 V1 flame retardance, and NF F 16-101/102 railway fire-smoke-toxicity compliance. Standard Schneider declarations for RoHS and REACH are available on request."},{"question":"What is the physical size of this contactor?","answer":"The LC2K0910D72 measures 90 mm wide, 58 mm high, and 57 mm deep. It fits standard DIN-rail or panel-mount enclosures."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K0910D72","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K0910D72 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}