{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K0910P72","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K0910P72","canonicalUrl":"https://aoctrl.com/schneider/LC2K0910P72","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K0910P72","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K0910P72, 3P, AC-3 ≤440 V 9 A, 1 NO, 230 V AC coil, IP20.","salesMarkdown":"It's a 3-pole unit rated AC-3 at 9 A up to 440 V, with a 230 V AC coil and one N.O. auxiliary contact. The AC-3 rating of 9 A at 440 V is the motor-switching current — this contactor is sized for a 3-phase motor drawing up to 9 A under full-load starting conditions. AC-1 (resistive) and AC-4 (inching/plugging) ratings also apply, so it covers both simple on/off and reversing duty cycles. The 230 V AC coil draws from a control transformer or line voltage; verify coil suppression matches the PLC output if driven from a solid-state source. The 57 mm depth and 90 mm width fit standard DIN-rail enclosures, but the reversing busbar adds width — check fill factor against the gland plate before committing the panel layout. Reversing contactors like this one are the standard building block for forward/reverse motor control in conveyors, hoists, pumps, and small machine tools. The preassembled reversing busbar saves panel wiring time compared to two separate contactors with an interlock kit.","metaTitle":"TeSys K LC2K0910P72 reversing contactor, 3P, AC-3 9A, 230VAC","metaDescription":"Obsolete TeSys K reversing contactor LC2K0910P72, 3P, AC-3 9A at 440V, 230VAC coil. Sourced to order against RFQ. IP20 finger-safe protection.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-1 AC-3 AC-3e","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/16b10378c67240ad9781d341538074b1.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2K0910P72/tesys-k-reversing-contactor-3p-ac3-440-v-9-a-1-no-230-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K0910P72/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"It is a 3-pole reversing contactor rated AC-3 at 9 A up to 440 V, with a 230 V AC coil and one N.O. auxiliary contact. It also carries AC-1 and AC-4 utilisation categories for resistive and inching duty."},{"question":"What is the physical size of the LC2K0910P72?","answer":"It measures 57 mm deep, 90 mm wide, and 58 mm high. The preassembled reversing busbar adds width beyond the base contactor footprint."},{"question":"What approvals or compliance documentation does this part carry?","answer":"The contactor carries IP20 finger-safe protection per VDE 0106, V1 flame retardance per UL 94, and meets NF F 16-101/102 for railway fire-smoke-toxicity. Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K0910P72","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K0910P72 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}