{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K12004P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K12004P7","canonicalUrl":"https://aoctrl.com/schneider/LC2K12004P7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K12004P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K LC2K12004P7, changeover contactor, 4-pole, 230 V AC 50/60 Hz control, AC-1 rated, preassembled with reversing power busbar.","salesMarkdown":"The 230 V AC 50/60 Hz coil pulls in at 0.8 to 1.15 Uc and drops out between 0.2 and 0.75 Uc, with an inrush of 30 VA at 20 °C. Rated for AC-1 resistive loads at 20 A, it handles the steady-state current of heaters, lighting banks, or transformer primaries where the switching duty is non-inductive. The AC-1 utilisation category (20 A at Ue ≤ 440 V) is the rating that governs real-world selection for resistive loads — it is not a motor-switching figure. For motor reversing you would need the AC-3 rating from a different variant in the same frame. The 4 NO power pole contact composition means all four poles close on energisation; the mechanical interlock prevents both contactors in a reversing pair from closing simultaneously, which is the standard safeguard against phase-to-phase shorts in a reversing starter. The rated breaking capacity of 110 A at 440 V (IEC 60947) tells you the contactor can interrupt a fault up to that level, though the associated fuse recommendation of 25 A gG or 25 A aM sets the practical overcurrent protection limit for the power circuit. Screw-clamp terminals accept one or two conductors from 0.34 to 4 mm² (solid or flexible with/without ferrule), with a tightening torque of 0.8 to 1.3 N·m using a Philips No. 2 or flat 6 mm driver. IP20 finger protection (per VDE 0106) means it is safe for open-panel mounting but not for washdown environments.","metaTitle":"Schneider Electric LC2K12004P7 TeSys K Changeover Contactor,","metaDescription":"Schneider Electric LC2K12004P7 TeSys K changeover contactor, 4-pole, 230VAC 50/60Hz control. AC-1 rated 20A resistive load. Mechanical interlock, preassembled reversing busbar. Cur","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"57 mm","Width":"90 mm","Height":"58 mm","Current":"20 A (at 16 A (at <70 °C) at 690 V AC AC-1 for power circuit","Voltage":"Power circuit: <= 690 V AC 50/60 Hz","IP Rating":"IP20","Application":"Resistive load","Coil Voltage":"230 V AC 50/60 Hz","Operating Time":"10...20 ms coil energisation and NO closing 10...20 ms coil de-energisation and NO opening","Product Status":"Active","Temp Storage Max":"80 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Temp Operating Max":"50 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...80 °C","Control Circuit Type":"AC at 50/60 Hz","Utilization Category":"AC-1","Electrical Life Cycles":"0.3 Mcycles 20 A AC-1 at Ue <= 440 V","Mechanical Life Cycles":"5 Mcycles","Main Product Or Component Type":"Changeover contactor","Ambient Air Temperature Operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8a2674b43646ee59536f3b540ee2fcf7.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K12004P7/tesys-k-changeover-contactor-4p-ac1-440-v-20-a-230-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K12004P7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K12004P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K12004P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}