{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K12013K7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K12013K7","canonicalUrl":"https://aoctrl.com/schneider/LC2K12013K7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K12013K7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 100 V AC coil, IP20.","salesMarkdown":"It switches three poles (3P) and is rated for AC-3 motor duty at 12 A up to 440 V, with a 100 V AC coil. The AC-3 rating of 12 A at 440 V governs motor switching — this contactor handles squirrel-cage motors up to roughly 5.5 kW at 400 V three-phase. The AC-1 rating (resistive load) will be higher, but for motor control, AC-3 is the figure that decides the BOM line. The 100 V AC coil means the control transformer or PLC output must supply that voltage; verify the control circuit voltage before specifying. Operating altitude of 2000 m without derating covers most installations; above that, consult the thermal derating curve. The -25 to 50 °C operating range suits standard industrial enclosures without forced cooling. ## Deployment context The preassembled reversing busbar reduces wiring time and eliminates the risk of miswiring the mechanical interlock between two contactors. The 57 mm depth and 90 mm width fit standard enclosure layouts, but the IP20 rating means it must be inside a locked or tool-accessible enclosure — not exposed to washdown or outdoor conditions.","metaTitle":"Schneider TeSys K LC2K12013K7 Reversing Contactor, 3P, 12A A","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 12A at 440V, 100V AC coil, IP20. Sourced to order against RFQ via surplus channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e4dfa92f1add9ba84beaa38580872ba8.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC2K12013K7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-100-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K12013K7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC2K12013K7?","answer":"It is a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 100 V AC coil. The IP20 enclosure suits enclosed panel mounting, and it operates from -25 to 50 °C at altitudes up to 2000 m without derating."},{"question":"What is the depth of the LC2K12013K7?","answer":"The depth is 57 mm, with a width of 90 mm and height of 58 mm, fitting standard DIN-rail or panel-mount enclosures."},{"question":"What series does the LC2K12013K7 belong to?","answer":"It is part of the TeSys K range from Schneider Electric, a compact contactor series for motor control and resistive load switching."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K12013K7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K12013K7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}