{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K12013K72","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K12013K72","canonicalUrl":"https://aoctrl.com/schneider/LC2K12013K72","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K12013K72","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC, 100 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"Rated AC-3 at 12 A up to 440 V and AC-1 for resistive loads, it handles typical small motor reversing duties on pumps, conveyors, or fans. The coil pulls in at 100 V AC, and the 1 NC auxiliary gives you a feedback or status contact for the controls side. The AC-4 rating covers plugging and inching duty, where the contactor breaks the motor at full locked-rotor current — if your application does frequent reversing under load, that's the rating to watch. The 690 V AC rated operational voltage on the power circuit means it can also serve in 480 V or 575 V systems, but the AC-3 current will derate above 440 V; the datasheet curve (not reproduced here) governs that. ## Mechanical and environmental toughness This contactor handles 10 to 15 Gn shock on the X, Y, and Z axes with the contacts closed, and 6 to 10 Gn when open — numbers that matter if the panel is mounted on a vibrating machine or near a press. Vibration resistance is 4 Gn closed, 2 Gn open, over 5 to 300 Hz. It's rated for operation up to 2000 m altitude without derating, so high-altitude plants are fine. Flame retardance meets UL 94 V1 and NF F 16-101/102, which is a plus for rail or transit applications where fire safety is a spec line.","metaTitle":"Schneider Electric LC2K12013K72 TeSys K Reversing Contactor,","metaDescription":"Schneider Electric LC2K12013K72 TeSys K reversing contactor, 3P, AC-3 12 A at 440 V, 100 VAC coil, IP20, active production. Source to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K12013K72","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 100 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bd20cf1f82876260c1656bda3087d266.pdf","sourceUrl":"https://www.se.com/in/en/product/LC2K12013K72/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-100-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"AC-3 motor switching rated 12 A at ≤440 V, AC-1 resistive load rated as well. Coil is 100 V AC. Power circuit rated for 690 V AC 50/60 Hz. IP20 finger protection."},{"question":"What compliance documentation is available for this part?","answer":"Flame retardance meets UL 94 V1 and NF F 16-101/102. Protective treatment conforms to IEC 60068 and DIN 50016. IP20 per VDE 0106. Standard Schneider Electric declarations for RoHS and REACH are available from the manufacturer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K12013K72","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K12013K72 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}