{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K12017E7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K12017E7","canonicalUrl":"https://aoctrl.com/schneider/LC2K12017E7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K12017E7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 48 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"The Schneider Electric LC2K12017E7 is a TeSys K reversing contactor, 3-pole, rated for AC-3 duty at 12 A up to 440 V with a 48 V AC coil. Rated for utilisation categories AC-1 (resistive loads), AC-3 (squirrel-cage motors — start/run), and AC-4 (plugging/inching), with a maximum operational voltage of 690 V AC on the power circuit. IP20 finger-safe terminals (per VDE 0106) and flame retardance V1 (UL 94) mean it's suited for standard control panel environments where accidental contact is prevented by the enclosure. Operating temperature range -25 to 50 °C, storage -50 to 80 °C. Preassembled with the reversing busbar means the interlock is already in place, saving panel wiring time. The 3 NO power poles handle the main motor circuit; the 1 NC auxiliary contact (per the description) can be used for status feedback or interlocking in the control circuit. Mechanical robustness rated for shocks up to 15 Gn (closed) and vibrations 4 Gn, 5–300 Hz (closed) per IEC 60068-2-27 and -2-6. Suitable for applications with moderate vibration, such as conveyors or pumps in industrial environments.","metaTitle":"TeSys K LC2K12017E7 Reversing Contactor, 12 A AC-3, 48 V AC","metaDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 48 V AC coil. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K12017E7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 48 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b354212e387374e6e4ed2b9cd12c9122.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC2K12017E7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-48-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"AC-3 rated 12 A at ≤ 440 V, with a 48 V AC coil. It also covers AC-1 (resistive) and AC-4 (plugging) categories. Maximum operational voltage on the power circuit is 690 V AC."},{"question":"What is the closest alternative in the TeSys K family?","answer":"Within the TeSys K range, other reversing contactors differ by coil voltage and current rating. The LC2K series shares the same footprint and preassembled busbar design; the deciding factor is matching the coil voltage (48 V AC here) and the motor full-load current (12 A AC-3). No pin-compatible drop-in with different ratings exists — the coil and current rating must match the application."},{"question":"What compliance documentation does this part carry?","answer":"Flame retardance V1 per UL 94, and IP20 per VDE 0106. Protective treatment TC per IEC 60068 and DIN 50016. The part is designed for use in control panels meeting IEC/UL standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K12017E7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K12017E7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}