{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1201FE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1201FE7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1201FE7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1201FE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 115 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"The 115 V AC coil pulls in cleanly; the built-in 1 NC auxiliary gives you a feedback contact for status or interlock. AC-1 (resistive) and AC-4 (inching/plugging) ratings are also listed, so it covers both continuous resistive loads and high-stress motor reversing cycles. IP20 finger protection per VDE 0106 means it's safe for open-panel mounting but not for washdown environments — keep it inside a cabinet. The preassembled reversing busbar saves panel space and wiring time compared to building the reversing circuit from two separate contactors and external bus work. Flame retardance meets UL 94 V1 and NF F 16-101/102, so it passes rail and industrial fire-safety requirements.","metaTitle":"Schneider TeSys K LC2K1201FE7 Reversing Contactor, 3P, 12 A,","metaDescription":"Schneider TeSys K LC2K1201FE7 reversing contactor, 3P, AC-3 12 A at 440 V, 115 V AC coil, 1 NC. Obsolete — sourced to order. RFQ for last-time buy.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/724380b969e30278568be76ccc7cfb65.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K1201FE7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-115-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K1201FE7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC2K1201FE7?","answer":"It is a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 115 V AC coil and one NC auxiliary contact. The power circuit is rated for 690 V AC 50/60 Hz. Operating temperature range is -25 to 50 °C."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries IP20 finger protection per VDE 0106, flame retardance to UL 94 V1 and NF F 16-101/102, and shock/vibration robustness per IEC 60068-2-27 and IEC 60068-2-6. Protective treatment conforms to IEC 60068 and DIN 50016."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1201FE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1201FE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}